Address Search: 2822 S BONANZA AV
Search
Parcel Attributes
| Parcel | 136124000 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| Water Course | Wash |
| City of Tucson Zoning | R-1 |
| Tucson Ward | Ward 4 |
| Tucson Registered Neighborhood | South Harrison |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Address: 2822 S BONANZA AV
Date - 08/19/2026 10:34 a.m.
Total Number Of Annexations & Original City Zoning (1)
Permits
Address: 2822 S BONANZA AV
Date - 08/19/2026 10:34 a.m.
Total Number Of Permits - (4)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TE-FPU-1124-00422 | Complete | 11/27/2024 | N/A | Floodplain Use | Hot tar roof replacement | |
| TC-RES-0624-03423 | Complete | 06/06/2024 | 09/08/2025 | Residential Building - One or Two Family | CE-VIO0524-02027 1. Remove existing roof Sheathing. No beams or rafter have been removed. 2. Remove existing plywood. 3. Install new plywood; approx. 75 sheets. (PLYWOOD WILL BE PROVIDED BY CUSTOMER) 4. Replace ALL fascia board. 5. Remove cooler/A/C unit for proper re-roofing and set it back, if applies. 6. Furnish and install a 75lb fiberglass base sheet and two layers #16lb of type IV fiberglass, finishing felts with hot asphalt in between each layer. 7. At damaged tail beam, install 2"X 12" block on top OR two blocks at side. 8. Install new 2in x 2in galvanized metal edge. 9. Seal all pipes and projections with APOC 264 Flash N Seal and t-tex fiber. 10. Apply fiber emulsion #293. 11. Apply two coats of Acrylic elastomeric #7000-3R white or desert tan paint color. 12. Clean area of roofing debris and remove from the premises unless otherwise specified. 13. Furnish four year warranty against leaks. We are not liable for any interior damage a leak may cause should one occur under warranty period/re-occur for leak related work. | |
| T02ME00564 | FINAL | 08/15/2002 | 02/15/2003 | MECH | REPLACE:SPLIT SYSTEM (APA) | |
| T02PL01524 | EXPIRED | 08/20/2002 | 03/16/2004 | PLUMB | INSTALL:NEW GAS LINE/RELOCATE METER |
Code Enforcement
Address: 2822 S BONANZA AV
Date - 08/19/2026 10:34 a.m.
Total Number Of Code Cases - (1)
| Case Number | Case Status | Entered Date | Exp Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| CE-VIO0524-02027 | Closed - Resolved | 05/29/2024 | 01/27/2025 | RWOP / Roofing removal without permit. |