Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0624-03423
Parcel: 136124000

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0624-03423
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/28/2024 PDSD Application Completeness REQUIRES RESUBMIT Still missing the following information that was not address from the previous comment: Resubmit with a complete Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. Identify live and dead loads. Show the location of the damage and repairs to be made. Provide a detail showing the proposed repairs to the 2x12 beam. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. Provide framing details to show attachment of new roof structures to existing structure.
Resubmit with a detailed comment response letter addressing all corrections made as well as indicating action taken. Resubmittals that do not contain a comment response may cause delay until the response letter has been received.
Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf