Permit Number - TC-DMO-1026-00188
Review Name: DEMOLITION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/29/2026 | Fire New Construction Express | NOT REQUIRED | |||
| 10/23/2026 | Site Engineering Fast | NOT REQUIRED | |||
| 10/30/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/23/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have any questions, please contact cdrc@tucsonaz.gov A separate interior permit is required for each unit. Please apply for a separate interior demo permit for each of the other 7 units. Please submit a change address request to remove 7 unit numbers from this permit. This permit is only for one unit. Once this review is complete, please resubmit construction plans with full address, with unit number, on all pages Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf |
||
| 10/29/2026 | Commercial Building Fast | REQUIRES RESUBMIT | Please submit a complete set of revised/corrected documents and a written response addressing each review comment and explaining how it was resolved. Please note that the original submittal was incomplete, and the review was based on the information provided. Additional comments may be issued upon subsequent review. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please provide site plan with unit or building numbers to indicate the structure/area for this permit.IBC 107.2.1 2. This is a Commercial project requiring all plans to be sealed and signed by an Architect or Engineer registered in the State of Arizona. accordance with SECTION 107 of the 2024 IBC and the PDSD Building Plan Requirement. 3. Please provide floor plans to clearly identify each unit number and the work to be done in each unit. IBC 107.2.1 4. Please obtain a NESHAP permit and provide a copy of the NESHAP permit with your next submittal. IBC 107.2.1 Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 10/30/2026 | Historic Fast | REQUIRES RESUBMIT | Historic comments: 1. Please clarify the extent of demolition of the ceiling. Historic review will be required if changes are proposed to the roof structure or form, or if any exterior re-roofing is required. If there will be no exterior changes to the roof, please note that on the plans. 2. Provide more information about the removal of exterior brick. What is the extent of the removal? If brick is to be removed, please note that brick will be replaced in-kind. Questions: PDSDHistoric@tucsonaz.gov. |
||
| 10/26/2026 | Site Zoning Fast | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner I Planning & Development Services Department – Current Zoning Review Section, Commercial PROJECT: TC-DMO-1026-00188 – Commercial – Roof Failure, Water Intrusion & Asbestos Abatement 404 S 5TH AV TUCSON, AZ 85701 (HO-3 Zoning) Demolition Review – 1st Review TRANSMITTAL DATE: October 26, 2026 1. COMMENT: Refer to Addressing Team comment referring to the need to have separate permits for each unit. 2. COMMENT: Per Comment 1, revise this permit to acknowledge one of the eight units and clearly label which of the eight units this permit is for. 3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 4. COMMENT: Corrected demolition building permit. 5. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home . Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . |
||
| 10/23/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |