Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1223-02914
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/05/2024 | Site Engineering | APPROVED | |||
04/09/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/02/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved with Comments Reason: Date Completed : 3/29/2024 12:18:37 AM GENERAL - DEFERRED SUBMITTAL REQUIREMENTS: The engineer of record has indicated that design of the prefabricated wood trusses and steel solar parking covers (carports) will be submitted as a Deferred Submittal. Please note that IBC Section 107.3.4.1 requires deferred submittals to be approved by the building official. The IBC further requires the following procedure be followed when permitting deferred submittals: 1. All submittals shall first be reviewed by design professional in responsible charge. 2. Design professional shall affix a notation that the deferred items are in general conformance with their design of the building. 3. They shall then be submitted for review by the building official. 4. No structural elements shall be installed until approved by building official. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 3/25/2024 11:45:43 AM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 1/8/2024 11:47:56 AM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 3/22/2024 10:53:30 AM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 3/23/2024 3:39:46 PM SECOND Plumbing Review: COMMENT 3 REMAINS\ RESOLVED-1). All Hose bibs on plan page P101 need shut off valves -IPC 606.2 RESOLVED-2). Roof deck on plan page A102 doesn't illustrate the required secondary scuppers as stated on plan page P102. -IPC 1108 PENDING RESULT OF RESPONSE COMMENT 3). Exterior Drinking fountain on plan page P101 needs to be protected from receiving rainwater into drain. -IPC 1101.3**** DESIGNER Response: = Communication has been initiated with the Tucson Building Official Clayton Trevillyan (clayton.trevillyan@tucsonaz.gov) to accept the minimal amount of rainwater which would enter the sanitary sewer from the water cooler. |
||
04/09/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T TC-COM-1223-02914 - TD-DEV-1223-00480 4431 E 22ND ST. – C-2/R-1 Multifamily (2nd Review) TRANSMITTAL: April 9, 2024 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in C-2 zone (UDC 4.7.21), Multifamily is a permitted use in the zone. 1. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Based on a wall height of 38’-5” shown from design grade to the top of parapet along the north side of the building the required perimeter yard setback to the north property line is 57’-8” proposed setback 53’-6”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. 2. The development package sheets provided in the building plan set either need to be the stamped approved plans, marked for reference only, or removed from the building set. If you elect to mark for reference only do not mark the utility plans and if you elect to remove the plans leave the utility plans in the so Plumbing can review. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
04/04/2024 | Fire New Construction | REVIEW COMPLETED | |||
03/20/2024 | PDSD Application Completeness | REVIEW COMPLETED |