Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1223-02769
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/16/2024 | Site Engineering | NOT REQUIRED | |||
02/28/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
01/24/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | NO CONSTRUCTION DOCUMENTS PROVIDED - APPLICANT WAITING FOR DDO APPROVAL PRIOR TO SUBMITTING CONSTRUCTION DOCUMENTS | ||
02/16/2024 | Fire New Construction | REQUIRES RESUBMIT | Submit construction documents john.vincent@tucsonaz.gov 5203495581 |
||
02/08/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-1223-02769 - TD-DEV-1223-00472 502 S FREMONT AV. – R-3 Multifamily (1st Review) TRANSMITTAL DATE: February 8, 2024 Please resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-3 zone (UDC 4.7.12). Multifamily is a permitted use in this zone (Table 4.8-2). See Use-Specific Standard 4.9.7.B.6 1. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. As dimensions from design grade to the highest point of the wall were it meets the eave Zoning cannot provide the required DDO comments. 2. Show the location of the 2nd floor along the south side of the building and provide a setback dimension to the second floor. Based on the 25’-6” dimension provide that setback is required to be 19’-2”. The following are DDO comments from the DP review: 1. COMMENT: 2-06.4.9.O – The required street perimeter yard setback for 14th St. is 20’-0”, 6.4.5.C.2.b, proposed setback appears to be 16’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. 2. COMMENT: 2-06.4.9.O – Based on a wall height of 22’-7” the required perimeter yard setback to the west property line is 16’-11”, proposed setback is 10’-0”. A DDO must be submitted and approved to reduce the setback. 3. COMMENT: 2-06.4.9.O – Based on a wall height of 10’-0” the required perimeter yard setback to the south property line is 10’-0”, proposed setback is 6’-0”. A DDO must be submitted and approved to reduce the setback. 4. The DDO shall be processed as a sub-permit to the DP. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
02/28/2024 | Water - PDSD | REQUIRES RESUBMIT | Provide construction documents that are complete and clearly indicate the extent of the proposed work . Reference: Section 107.2.1, IBC 2018 | ||
01/24/2024 | PDSD Application Completeness | REVIEW COMPLETED |