Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-1026-01670
Parcel: 14122004U

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-1026-01670
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2026 Site Engineering APPROVED
10/23/2026 Fire New Construction NOT REQUIRED
10/22/2026 Water - PDSD NOT REQUIRED
10/25/2026 Commercial Building REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1026-01670
ADDRESS/PARCEL: (7762 E SCIENCE PARK DR TUCSON, AZ 85747)
Submit your revised drawings along with a ***detailed response letter***, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
1. TOTAL NUMBER OF SHEETS: The title block indicates 80 sheets for this project, 11 sheets were submitted. Is there more sheets that should be submitted? If not, please correct the sheet numbering system. Please include a sheet index on the cover sheet.
2. SHEET 15 OF 80 PRE-FABRICATED DISINFECTING BUILDING, WELL PIPING AND EQUIPMENT #8: Please submit the Structural Calculation and detail drawings of this structure, sealed/signed/dated by a State of Arizona licensed Structural Engineer.
3. SHEET 25 OF 80: Please have Structural Engineer Alex Lane Firth submit his sealed/signed/dated structural engineer calculations of his Chlorination System Rack Shade Structure.
4. THE BUILDING PERMIT DESCRIPTON IS, “Modify the F-009 well site to deliver water from the F-009B well and F2 water service area (WSA) to the G2 WSA. This addition/alteration is for the new shade structure and well discharge header located at the F-009 well site.” Please add this project description on the cover sheet, making clear as to the scope of this project.
5. Please enter the dollar valuation of the project (it is currently shown as $0.0.
6. Please resubmit.
10/19/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-1026-01670 (7762 E SCIENCE PARK DR TUCSON, AZ 85747)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Provide complete set of electrical plans that covers the scope of work being proposed.
10/22/2026 Commercial Plumbing REQUIRES RESUBMIT If the installation of the safety shower will be included within this activity, provide sheets C-7 and C-12. Reference: Section 107.2.1, IBC 2024.

If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
10/21/2026 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Jeffrey W. Cassidy, Planner I
Planning & Development Services Department – Current Zoning Review Section, Commercial

PROJECT:
TC-COM-1026-01670 – Commercial – This addition-alteration is for new shade structure & well discharge header
7762 E SCIENCE PARK DR TUCSON, AZ 85747 (I-2 Zoning)
Commercial Building Plan Review – 1st Review

TRANSMITTAL DATE:
October 21, 2026

1. COMMENT: On the cover sheet, provide a sheet index to a) account for all the drawings provided (11) and b) to match the sheet numbers and names.

2. COMMENT: Update each sheets title block to be reflective of the sheet in sequential order and the total sheet set. Currently, not only are the sheets labeled are not in sequential order but are followed by ‘80’ as the total number of sheets. Ie Sheet 1 of 11.

3. COMMENT: On the second sheet, under permit/zoning notes, update general note 4 height limitation from 24’-0” to 140’-0”.

4. COMMENT: On the second sheet, under permit/zoning notes, update general note 5 use specific standards to not have any.

5. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

6. COMMENT: Corrected commercial building permit.

7. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home .

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .
10/09/2026 PDSD Application Completeness Express REVIEW COMPLETED