Address Search: 7762 E SCIENCE PARK DR
Search
Parcel Attributes
| Parcel | 14122004U |
|---|---|
| Jurisdiction | Tucson, Pima County |
| Water Course | Wash |
| City of Tucson Zoning | I-2, RH, I-1 |
| Airport Environs Zone | NCZ-A Davis Monthan AEZ Paddle |
| Tucson Ward | Ward 4 |
| Flood Related Information | FEMA Floodplain Area |
| Major Street & Route | Gateway Route, Arterial or Collector |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Address: 7762 E SCIENCE PARK DR
Date - 09/22/2026 12:45 a.m.
Total Number Of Annexations & Original City Zoning (1)
Rezoning Cases
Date - 09/22/2026 12:45 a.m.
Total Number Of Rezone Cases - (1)
| Case No. | Description | New Zone | Status | Status Date |
|---|---|---|---|---|
| C9-06-02 | AZ Board of Regents - Kolb Rd | R-2 | Expired | 01/23/2006 |
Permits
Address: 7762 E SCIENCE PARK DR
Date - 09/22/2026 12:45 a.m.
Total Number Of Permits - (1)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-UTL-0826-00163 | In Review | 08/28/2026 | N/A | Utilities Permit | This plan will modify the F-009 well site to deliver water from the F-009B well and F2 water service area(WSA) to the G2 WSA. Modifications include: equipping the F-009B well, changing the booster station pumps, installing new chlorination equipment, modifying the site control panel, and adding site piping and an MOV flow control valve to connect to the F2 WSA. Additional work includes rehabilitation of the reservoir and above-ground piping. |
Plans
Address: 7762 E SCIENCE PARK DR
Date - 09/22/2026 12:45 a.m.
Total Number Of Plans - (3)
| Plan Number | Status | Application Date | Exp Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| CIP-0126-00001 | Review Complete | 01/16/2026 | N/A | -- (CIP) Development Site + Commercial Structure | TW-PLAN-0326-0003: TW CIP Plan review has moved to TW-PLAN Work Class records. Tucson Water capital improvement project to refurbish and modify the F-009 well site to serve the G-zone water service area. | |
| CIP-0926-00012 | Submitted | 09/16/2026 | N/A | -- (CIP) Commercial Structure | This plan will modify the F-009 well site to deliver water from the F-009B well and F2 water service area(WSA) to the G2 WSA. Commercial structures requiring permit are the chlorine shade structure and the well head. Drawings and calculations have been provided for both. | |
| TW-PLAN-0326-0003 | Review Complete | 09/01/2024 | N/A | -- TW Capital Plan | This plan will modify the F-009 well site to deliver water from the F-009B well and F2 water service area(WSA) to the G2 WSA. Modifications include: equipping the F-009B well, changing the booster station pumps, installing new chlorination equipment, modifying the site control panel, and adding site piping and an MOV flow control valve to connect to the F2 WSA. Additional work includes rehabilitation of the reservoir and above-ground piping. |