Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0825-01545
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2025 | Site Zoning Standard | NOT REQUIRED | |||
| 09/10/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/10/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Alteration level 3 commercial fee | ||
| 08/27/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0825-01545 (3300 S PARK AV Unit:BLDG 2 TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Each building or structure shall be supplied by a single branch circuit or feeder, NEC 225.30. 2. Provide a grounding electrode on the Riser Diagram the sub-panel, and each separate building or structure supplied by feeders or branch circuits, NEC 250.32. 3. Provide a disconnecting means at each building or structure where the branch circuits or feeders enter the buildings, per NEC 225.30 & 225.32. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/27/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0825-01545 (3300 S PARK AV Unit:BLDG 2 TUCSON, AZ 85713) 1. Provide manufacture’s specification sheets for outdoor lighting fixtures showing full cutoff status. |
||
| 09/05/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0825-01545 Location: 3300 S Park AV Review Date: 9/5/2025 Site Engineering Comments: 1. Site Engineering will be unable to approve permit TC-COM-0825-01545 until the associated Development Package TD-DEV-0825-00212 has been reviewed and approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 09/04/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 08/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |