Permit Number: TC-COM-0626-00977
Parcel: 14039052F

Review Status: In Review

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0626-00977
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
09/17/2026 Commercial Building Standard APPROVED
09/23/2026 Commercial Mechanical Standard APPROVED
09/23/2026 Water - PDSD Standard APPROVED
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A Landfill Standard PENDING ASSIGNMENT
09/23/2026 Commercial Plumbing Standard REQUIRES RESUBMIT 1. Revise the Electric Water Heater Detail, 3/P501, to show that the Holdrite platform is to be used instead of a field-fabricated platform. [Initial comment: Provide structural calculations for the mounting shelf for the water heater to show that the water heater will be safely supported from the building structure. Reference: Section 301.2, IPC 2024.]
2. Clarify that the ½” hot water branch off of the hot water circulating loop (i.e. the hot water source) is no longer than 24 inches. The plumbing plan (P201) does not clearly illustrate the path of the circulating hot water loop. (Note: add a check valve between the circulating pump and the downstream shut off valve to prevent cold water from entering the hot water loop when the pump is off.) [Initial comment: Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5.1, IECC 2024.]

If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
09/03/2026 PDSD Application Completeness Express REVIEW COMPLETED