Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0525-00978
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/16/2025 | Outdoor Lighting | APPROVED | |||
| 06/06/2025 | Site Engineering | APPROVED | |||
| 06/02/2025 | Site Zoning | APPROVED | |||
| 06/06/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/02/2025 | Commercial Building | REQUIRES RESUBMIT | June 2, 2025 1st Review Light+Path Architecture LLC Attn: Brian G. Hagedon 475 S. Gollob Road Tucson, Arizona 85710 Re: TEEN CHALLENGE MENS CENTER NEW EXTERIOR CANOPY City of Tucson Permit Number: TC-COM-0525-00978 Stantec Project Number: 185215066 Stantec File Number: TUC-25-056 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms U V-B 1,408 8 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, high-strength bolts, field welding, cold-formed steel deck. ARCHITECTURAL COMMENTS There are no comments. STRUCTURAL COMMENTS Sheet S3.0 1. Detail 601 refers to a “Typical Bolt Schedule” for size, type and number of bolts. The plans do not appear to contain a schedule for this. Please clarify. 2. Detail 611 appears to be missing a dimension between the steel beams. Also, please clarify the symbols at the steel roof deck of this detail. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 06/02/2025 | Commercial Electrical | REQUIRES RESUBMIT | June 2, 2025 1st Review Light+Path Architecture LLC Attn: Brian G. Hagedon 475 S. Gollob Road Tucson, Arizona 85710 Re: TEEN CHALLENGE MENS CENTER NEW EXTERIOR CANOPY City of Tucson Permit Number: TC-COM-0525-00978 Stantec Project Number: 185215066 Stantec File Number: TUC-25-056 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms U V-B 1,408 8 No No Separate Permits: None. Deferred Submittals: None. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, high-strength bolts, field welding, cold-formed steel deck. ARCHITECTURAL COMMENTS There are no comments. STRUCTURAL COMMENTS Sheet S3.0 1. Detail 601 refers to a “Typical Bolt Schedule” for size, type and number of bolts. The plans do not appear to contain a schedule for this. Please clarify. 2. Detail 611 appears to be missing a dimension between the steel beams. Also, please clarify the symbols at the steel roof deck of this detail. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 05/15/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |