Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0424-00699
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/17/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | June 13, 2024 2nd Review Seaver Franks Architects Attn: Rick Huch/ Nurlan Herburger 2552 N. Alvernon Way Tucson, Arizona 85712 Re: BOYS AND GIRLS CLUB TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0424-00699 Stantec Project Number: 185215066 Stantec File Number: TUC-24-040 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms E III-B 17,169 399 Yes Yes Separate Permits: Automatic fire sprinklers, kitchen hood suppression system and fire alarm Deferred Submittals: None. Special Inspections: Field welding. ARCHITECTURAL COMMENTS General 1. Addressed. 2. Addressed. 3. The plan-set indicates the installation of new mechanical units on the roof ranging from 450lbs – 850lbs. These units appear to be in different areas of the roof than the original units. Please provide an engineering analysis that indicates the proposed units can be placed at the locations indicated without additional reinforcement. Additionally, the proposed type 1 hood indicates a hanging weight of 559lbs. Please provide a structural analysis that the existing roof can support the hood and a design to accompany. [Ref. IBC 2018 Sec. 1604.4] Still Required: The structural plans do not include a design for a method of attachment of the hanger rods to the roof joists. {This comment is also included in the ‘Structural Comments’ section.} 4. Addressed. 5. New Comment: Note on the cover of the drawings that special inspection is required for field welding. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form. Sheet A5.0 1. Addressed. 2. Addressed. STRUCTURAL COMMENTS General 1. The plan-set indicates the installation of new mechanical units on the roof ranging from 450lbs – 850lb. these units appear to be in different areas of the roof than the original units. Please provide an engineering analysis that the proposed units can be placed at the locations indicated without additional reinforcement. Additionally, the proposed type 1 hood indicates a hanging weight of 559lbs. Please provide a structural analysis that the existing roof can support the hood. [Ref. IBC 2018 Sec. 1604.4] Still Required: The structural plans do not include a design for a method of attachment of the hanger rods to the roof joists. MECHANICAL COMMENTS Sheet M2.0 1. Addressed. PLUMBING COMMENTS Sheet P1.0 1. Addressed. 2. New Comment: The new floor sink to the left of the booster pump in the pump room does not indicate a connection to the sewer. This floor sink also does not include a fixture mark. Please revise. Sheet P1.1 1. New Comment: The plans do not indicate a gas connection to the gas water heater. Please revise. Sheet P2.0 1. Addressed. ELECTRICAL COMMENTS 1. There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 06/11/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |