Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0325-00540
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/04/2025 | Commercial Plumbing Standard | APPROVED | Reviewer - See Internal Notes Plumbing(P) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 4/4/2025 2:51:34 AM 2717 E Corona Road IT office improvements TC-COM-0325-00539 Unit 110 TC-COM-0325-00544 Unit 190 TC-COM-0325-00543 Unit 170 TC-COM-0325-00542 Unit 160 TC-COM-0325-00541 Unit 150 TC-COM-0325-00540 Unit 140 |
||
| 04/07/2025 | Site Zoning Standard | APPROVED | Reviewer - See Internal Notes | ||
| 04/15/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | Reviewer - See Internal Notes | ||
| 04/04/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Reviewer - See Internal Notes Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 4/4/2025 2:56:21 AM 2717 E Corona Road IT office improvements TC-COM-0325-00539 Unit 110 TC-COM-0325-00544 Unit 190 TC-COM-0325-00543 Unit 170 TC-COM-0325-00542 Unit 160 TC-COM-0325-00541 Unit 150 TC-COM-0325-00540 Unit 140 1. Structural Calculations- Update the codes listed on the calculations to indicate the City of Tucson and remove the reference to the State of Nevada. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 4/4/2025 2:53:14 AM 2717 E Corona Road IT office improvements TC-COM-0325-00539 Unit 110 TC-COM-0325-00544 Unit 190 TC-COM-0325-00543 Unit 170 TC-COM-0325-00542 Unit 160 TC-COM-0325-00541 Unit 150 TC-COM-0325-00540 Unit 140 All corrections must be clouded, delta numbered, with a brief explanation within the plan sheet or the title block. Please include with the resubmittal a separate response narrative, which is numbered or itemized to correspond to each of the noted plan review comments items. 1. General Comment- COMcheck Envelope- Compliance Certificate for Unit 140 was missing from the submittal. 2. Sheet G0.0 Cover Sheet- Note on the drawings that additional safety systems may be required depending on the final tenant specific use occupancy classification. 3. Sheet G0.0 Cover Sheet- Correct the Sheet Index so it matches the drawings that were provided. Sheets P4.7 and P4.8 are missing on the list as well as sheets E2.4 and E2.5. Sheets M5.1 and M5.2 are listed twice. 4. Sheet G0.0 Cover Sheet- Indicate the Alteration Level of the work in the General Building Code Summary that is in accordance with 2018 IEBC Section 600. 5. Sheet A1.1 Overall Suite 110- Correct the total occupancy on the Occupancy Load Schedule. The total occupancy when rounded up should be 91. 2018 IBC 1004.5. 6. Sheet A1.3 Overall Suite 140- Correct the total occupancy on the Occupancy Load Schedule. The total occupancy when rounded up should be 76. 2018 IBC 1004.5. 7. Sheet A1.5 Overall Suite 150- Correct the total occupancy on the Occupancy Load Schedule. The total occupancy when rounded up should be 15 + 46 for a total of 61. 2018 IBC 1004.5. 8. Sheet A1.7 Overall Suite 160- Correct the total occupancy on the Occupancy Load Schedule. The total occupancy when rounded up should be 8 + 23 for a total of 31. 2018 IBC 1004.5. 9. Sheet A1.9 Overall Suite 170- Correct the total occupancy on the Occupancy Load Schedule. The total occupancy when rounded up should be 8 + 23 for a total of 31. 2018 IBC 1004.5. 10. Sheet A1.11 Overall Suite 190- Correct the total occupancy on the Occupancy Load Schedule. The total occupancy when rounded up should be 15 + 45 for a total of 60. 2018 IBC 1004.5. |
||
| 04/04/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Reviewer - See Internal Notes Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 4/4/2025 2:54:21 AM 2717 E Corona Road IT office improvements TC-COM-0325-00539 Unit 110 TC-COM-0325-00544 Unit 190 TC-COM-0325-00543 Unit 170 TC-COM-0325-00542 Unit 160 TC-COM-0325-00541 Unit 150 TC-COM-0325-00540 Unit 140 1. General Comment- Provide an Interior Lighting COMcheck Compliance Certificate or other approved methodology for the project for the new proposed lighting. 2018 IECC. |
||
| 04/04/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Reviewer - See Internal Notes Mechanical(M) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 4/4/2025 2:55:24 AM 2717 E Corona Road IT office improvements TC-COM-0325-00539 Unit 110 TC-COM-0325-00544 Unit 190 TC-COM-0325-00543 Unit 170 TC-COM-0325-00542 Unit 160 TC-COM-0325-00541 Unit 150 TC-COM-0325-00540 Unit 140 All corrections must be clouded, delta numbered, with a brief explanation within the plan sheet or the title block. Please include with the resubmittal a separate response narrative, which is numbered or itemized to correspond to each of the noted plan review comments items. 1. Sheet M2.0 Mechanical Overall Plan- Note the location of the permanently installed roof ladder or hatch on the plan, the existing roof is greater than 16 feet above grade. 2018 IMC 306.5 |
||
| 04/15/2025 | Water - PDSD Standard | REQUIRES RESUBMIT | Reviewer - See Internal Notes Provide the size of the water meter serving this suite, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018. |
||
| 04/02/2025 | Fire New Construction Standard | REVIEW COMPLETED | SUITE140: Fire alarm or fire sprinklers systems alteration requires a separate permit. |
||
| 03/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 04/14/2025 | Site Engineering Standard | REVIEW COMPLETED | Reviewer - See Internal Notes |