Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - T22CM02647
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/20/2023 | Commercial Plumbing | APPROVED | Restamp Required | ||
| 03/16/2023 | External Reviewers - SAFEBuilt | APPROVED | Activity Number: T22CM02647 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances BUILDING REVIEW COMMENTS: Conditionally Approved 1. The occupant load provided on sheet C-1 still exceeds the maximum occupant load allowed by the City of Tucson Unified Development Code Section 4.9.4.B.1 of 10 occupants. Correct the occupant load on sheet C1. MECHANICAL REVIEW COMMENTS: Conditionally Approved 3. Provide an approved ventilation calculation table. (i.g. the total area for this building is 6,080 square feet, the total area your providing in your table is 5,300 square feet, your missing 780 square feet, also your lumping all the rooms as offices, when you got different rooms that must be calculated as different occupancies with different CFM requirements than an office. for example a dining room, Zuma room, sleeping room requires different outside air than an office and they must be listed accordingly sheet M4 (IMC2018,106.3.1) Complied 4. Public restrooms require 70 cfm of exhaust air you got 60 cfm and you don't specify if it is continuous or intermittent exhaust sheet M4 (IMC2018,403.3.1.1) on your ventilation calcs's you got 3 restroom's with a total combined cfm capacity of 150 cfm, with no note that says continuous ventilation, and then you got a exhaust air fan schedule, that says exhaust fan 85 cfm 1. it contradicts the numbers in your ventilation calc's and 2. it say's it is interlocked with the air handler but it doesn't say it is continuous like you imply in your written response. you must submit a revised plan that matches your written response on sheet M4 Complied Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Conditionally Approved Fourth Plumbing Review: Ok Subject To Field Inspections 1). OK 2). OK 3 thru 10 OK If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
| 03/16/2023 | Site Engineering | APPROVED | Restamp Required | ||
| 03/20/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/16/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM02647 402 W MEDINA RD Zoning R-1 TRANSMITTAL DATE:March 16, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed 1.COMMENT: This site is subject to UDC section 4.9.4.B.1 “The use is for a maximum of ten persons” The occupancy load has 15 occupancy per UDC 4.9.4.B If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov Resubmittal process https://www.tucsonaz.gov/files/pdsd/pdfs/Resubmittals.pdf |
||
| 03/17/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 03/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |