Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE REVIEW v.2
Permit Number - DP22-0214
Review Name: DEVELOPMENT PACKAGE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/09/2023 | Commercial Plumbing | APPROVED | |||
| 12/16/2022 | Site Landscape | APPROVED | |||
| 12/08/2022 | External Reviewers - Pima County Addressing | NOT REQUIRED | |||
| 01/25/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 01/25/2023 | External Reviewers - COT Environmental Services | REQUIRES RESUBMIT | Review still required however will change status to requires resubmit to allow for permit to move forward with the start of corrections. | ||
| 01/05/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Ensure all basins have a minimum freeboard of 6" from WSEL to Top, see basins 3, 5, 6, and 7 (COT Ret/Det manual 4.4.1.1) 2. Detail 9/G3.0 shows 1.5' space between wheel stop and sidewalk curb, while the site plan calls out 2.5'. Please clarify and ensure 4' of pedestrian space is maintained with 2.5' vehicle overhang 3. Provide callout for curbslot on Southern basin including TC and AC measurements 4. Provide invert elevations for all basin inlets in the Northern basin, provide elevations for the basin outlet in the northern basin as well as those in WH basins 1 and 7 |
||
| 12/07/2022 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Corona Commerce – New Industrial Park Development Package (2nd Review) DP22-0214 TRANSMITTAL DATE: December 07, 2022 DUE DATE: January 04, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 7, 2023. CONTENT REQUIREMENTS The section corners were not labeled. Provide the sections labels by number at the intersection of Country Club & Los Reales. COMMENT: 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled on the location map. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes As you remove the note totally provide a general note stating the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. COMMENT: 2-06.4.7.A.4 – Under General Notes you list Use Specific Standards for P-1 zone, remove this reference from the plan as the PI zone is not applicable to this site. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. This comment was not addressed. COMMENT: 2-06.4.9.A - As this site is made up of two parcels, 140-42-026A & 140-42-0250, a lot combination is required. Provide a copy of the approved Pima County Assessor’s Combo Request form or a recorded Covenant Regarding Development and Use of Real Property with your next submittal. This comment was not addressed correctly. Review UDC Article 7.4.6.H.3 and provide the correct dimension for the location of the wheel stop. COMMENT: 2-06.4.9.H.5.a – Detail 9 sheet 9 references detail 2/G3.0 and points to a wheel stop. Detail 2 is a bollard detail. Provide a location dimension for the wheel stop that meets the requirements of UDC Article 7.4.6.H.3. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
||
| 12/05/2022 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 12/28/2022 | Fire New Construction | REVIEW COMPLETED |