Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - DP21-0157
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2025 | Site Landscape Standard | APPROVED | |||
| 06/20/2025 | Site Zoning Standard | APPROVED | |||
| 06/10/2025 | External Reviewers - PC RFCD Standard | REQUIRES RESUBMIT | I have the following comments: 1. Label on Figure 1 in the report the proposed discharge from the force main, the Q100 discharge from the existing culvert, and identify the predeveloped discharge where these 2 discharges meet. 2. Provide discussion as to any necessary erosion control for the force main discharge location, and discuss the ramifications for the revised storm drain design for the easements and maintenance agreements in this area. Thanks, JJ Jim “JJ” Janecek, P.E., CFM Development Review Section Manager Engineering and Landscape Architecture Division Pima County Regional Flood Control District 201 N. Stone Avenue, 9th Floor Tucson, AZ 85701 520-724-4661 |
||
| 06/20/2025 | Site Engineering Standard | REQUIRES RESUBMIT | 1. See that PCRFCD comments are addressed. 2. The use of underground storage and will be acceptable for this project on the condition that the Underground Storage Standards are met from section 4.13 of the Design Standards for Stormwater Detention and Retention Manual. Please include a letter in the next submittal addressing each standard found in section 4.13 and how it is being met. 3. The use of a pump will be acceptable for this project on the condition that the Pump Standards are met from section 4.18 of the Design Standards for Stormwater Detention and Retention Manual. Please include a letter in the next submittal addressing each standard found in section 4.18 and how it is being met. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 05/19/2025 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 05/29/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Pima County Regional Flood Control District (RFCD) | ||
| 06/18/2025 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 06/11/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 05/28/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 05/27/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED |