| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Bldg Permits - Post Review Express | PENDING ASSIGNMENT | ||||
| CDRC Post Review Express | PENDING ASSIGNMENT | ||||
| Commercial Building | PENDING ASSIGNMENT | ||||
| Commercial Mechanical | PENDING ASSIGNMENT | ||||
| Commercial Plumbing | PENDING ASSIGNMENT | ||||
| NPPO | PENDING ASSIGNMENT | ||||
| Site Landscape | PENDING ASSIGNMENT | ||||
| Site Zoning | PENDING ASSIGNMENT | ||||
| Storm to Shade Review | PENDING ASSIGNMENT | ||||
| TW Planning and Engineering Review | PENDING ASSIGNMENT | ||||
| Water - PDSD | PENDING ASSIGNMENT | ||||
| Building Official | REVIEW COMPLETED | ||||
| Commercial Electrical | REVIEW COMPLETED | Commercial Electrical Review CIP-0126-00001 (7762 E SCIENCE PARK DR TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Provide the complete set of electrical plans sealed by a qualified Electrical Engineer, Registered in the State of Arizona. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
|||
| Fire New Construction | REVIEW COMPLETED | No Comments | |||
| Outdoor Lighting | REVIEW COMPLETED | No comments. | |||
| Site Engineering | REVIEW COMPLETED | Site engineering has no comments at this time |