Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Development Package
Address NEW:
5220 S NOGALES HY
Apply Date:
06/25/2023
Applicant:
RHONDA RAWSON
Description:
ADDITION OF A DRIVE THRU

Permit Reviews

Permit Number - TD-DEV-0623-00287
Permit Status: Complete
Permit Description: ADDITION OF A DRIVE THRU
Start Date Submittal Complete Date Status  
06/26/2023 DEVELOPMENT PACKAGE NEW v.1 08/30/2023 APPROVED Review Details

Outstanding Inspections

Permit Status: Complete
Permit Number: TD-DEV-0623-00287
Permite Description: ADDITION OF A DRIVE THRU
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/26/2025 SITE - Zoning Final N/A Not Ready I talked to Brad Hoge about how DP plans were not followed. He will coordinate with other stakeholders to Revise the DP.
07/02/2025 ENGR Engineering Final N/A Not Ready Approved Plans show 2 short term "U" racks in the detail. However it shows 1 in the Site Plan so 1 is okay. The U rack has been installed in the wrong location. It is installed to the west of entry patio instead of under it per plan.

No long term bike parking has been installed per plan.

The ADA van Accessible Parking sign must be installed in the correct location. It has been left in wrong place after restriping. The signage will need to be included for both locations.

ADA Parking space is the wrong width by the entryway. Per plan it is 12.5'. It is less that.
Per plan that is the only parking space by the entryway.

The wheel stops to the East of the building need to be addressed. They are not shown on the plan because that side is not intended as parking. In Addition to this condition there is no Grade Separation between the East Existing Entry Way Patio and the 2-way driveway... See attached picture of existing condition.

Completed Inspections

Permit Status: Complete
Permit Number: TD-DEV-0623-00287
Permit Description: ADDITION OF A DRIVE THRU
Total Completed Inspections - 1
Date Description Inspector Results Comments
07/21/2025 ENGR Engineering Final Passed

Documents

File Name Document Type  
5220 S NOGALES HY TUCSON AZ 85706.PDF DOCUMENTS VIEW
APPROVED DEVELOPMENT LETTER-MERGE.PDF DOCUMENTS VIEW
GIS FACILITIES AD-HOC T81641.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_5220 S NOGALES HWY_V1.PDF DOCUMENTS VIEW
TD-DEV-0623-00287 COMMENT LETTER 08.01.23.PDF DOCUMENTS VIEW
1_5220 S NOGALES HWY_V1 (1).PDF PLANS UNDER REVIEW VIEW