Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Apply Date:
12/30/2024
Applicant:
GGV Designs
Description:
Renovate Garage into ADU

Permit Reviews

Permit Number - TC-RES-1224-07502
Permit Status: Inspections
Permit Description: Renovate Garage into ADU
Start Date Submittal Complete Date Status  
04/28/2025 RESIDENTIAL NEW DWELLING v.3 04/30/2025 IN REVIEW Review Details
05/20/2025 RESTAMP - RESIDENTIAL v.1 05/20/2025 APPROVED Review Details
05/02/2025 RESIDENTIAL NEW DWELLING v.4 05/20/2025 APPROVED Review Details
02/21/2025 RESIDENTIAL NEW DWELLING v.2 03/17/2025 REQUIRES RESUBMIT Review Details
01/06/2025 RESIDENTIAL NEW DWELLING v.1 02/05/2025 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-1224-07502
Permit Status: Inspections
Permit Description: Renovate Garage into ADU
Date Description Comments
01/14/2025 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
01/06/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-1224-07502
Permite Description: Renovate Garage into ADU
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
07/21/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Insulation is in place at both walls and ceiling. Electrical boxes are not made up throughout. Grommets are missing at both exhaust fans. Nail plates are required at any lines that are less than 1 1/4" from the face of the studs. Fire blocking is required at soffit areas. Customer stated that the inspection was approved pending smoke detectors and sub panel. Plans call for an all in one panel. 7/21/2025
07/21/2025 COT - RSEL - Grounding/Bonding N/A Re-inspection required Insulation is in place at both walls and ceiling. Electrical boxes are not made up throughout. Grommets are missing at both exhaust fans. Nail plates are required at any lines that are less than 1 1/4" from the face of the studs. Fire blocking is required at soffit areas. Customer stated that the inspection was approved pending smoke detectors and sub panel. Plans call for an all in one panel. 7/21/2025
07/21/2025 COT - RSPL - Rough Soil N/A Re-inspection required Need to verify the depth and tracer wire to the point of connection to sewer. Plumbing has been backfilled prior to inspection. 7/21/2025

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-1224-07502
Permit Description: Renovate Garage into ADU
Total Completed Inspections - 2
Date Description Inspector Results Comments
05/29/2025 COT - RSEL - Electrical Underground Passed
05/29/2025 BULD - Electrical Clearance Passed 5/29/25
TEP CLEARANCE: INCR; UNIT 2.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-4_PLANS_2024.62 KSW SYLVANE_V2.PDF DOCUMENTS VIEW
DDO-25-30 DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO-25-30 NOTICE.PDF SPECIAL APPLICATIONS VIEW
DDO-25-30 APPLICATION.PDF SPECIAL APPLICATIONS VIEW
DDO-25-30 PLAN SET.PDF SPECIAL APPLICATIONS VIEW