Permit: TC-RES-1124-06786
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3544 S 7TH AV
Address NEW:
3544 S 7TH AV
Apply Date:
11/21/2024
Applicant:
Description:
Renovate SFR
Permit Reviews
Permit Number - TC-RES-1124-06786
Permit Status: Inspections complete
Permit Description: Renovate SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/22/2024 | RESIDENTIAL NEW DWELLING v.1 | 12/31/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-1124-06786
Permit Status: Inspections complete
Permit Description: Renovate SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/12/2024 | Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents. |
Conditions
Permit Number - TC-RES-1124-06786
Permit Status: Inspections complete
Permit Description: Renovate SFR
| Date | Description | Comments |
|---|---|---|
| 11/22/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1124-06786
Permite Description: Renovate SFR
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 9-29-25: prior to building final submit a detail regarding fur out. Wrong hardware at post to beam used at great room and missing A35's. Show detail identifying type of screw, size, nut and spacing on north post where screw/nut are drilled through cmu wall, replace 7/16" anchor bolt with a 1/2" anchor located at northwest corner of building, add shot pins to to sill plate at 32" o.c., add backing for shower & water closet, provide clarification on whether trusses or rafters are to be used and identify sistering of rafters, missing foam gasket underneath exterior sill plate- see P5/Detail 13 for information. STOPPED INSPECTION-ADDITIONAL ITEMS MY BE NOTED. |
| 03/25/2026 | RSBU - Building Final | N/A | Re-inspection required | 3-25-26: unable to open gate. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1124-06786
Permit Description: Renovate SFR
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2025 | BULD - Electrical Clearance | Passed | Service up graded to 200 amp service. | |
| 09/16/2025 | COT - RSPL - Rough Soil | Passed | 9.16.2025 Okay to backfill, shading required. |
|
| 09/16/2025 | COT - RSPL - Sewer | Passed | 9.16.2025 Okay to backfill, shading required. |
|
| 09/16/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 10/02/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10.2.25 Corrections made |
|
| 11/19/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 11.19.2025 Approved per plan, added Boca plates to DWVs at sill plates. |
|
| 03/25/2026 | RSBU - Building Final | Passed | 3-25-26: building final approved. | |
| 03/25/2026 | COT - RSEL - Outdoor Lighting | Passed | 3-25-26: outdoor lighting | |
| 03/25/2026 | COT - RSME - Mechanical Final | Passed | 3-25-26: mechanical final approved. | |
| 03/25/2026 | COT - RSPL - Plumbing Final | Passed | 3-25-26: plumbing final approved. | |
| 03/25/2026 | COT - RSEL - Grounding/Bonding | Passed | 3-25-26: approved. |