Permit: TC-RES-1124-06786

Parcel: 119044540


Addresses:

3544 S 7TH AV

Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
09/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready 9.16.2025
Not ready.
09/29/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 9-29-25: prior to building final submit a detail regarding fur out. Wrong hardware at post to beam used at great room and missing A35's. Show detail identifying type of screw, size, nut and spacing on north post where screw/nut are drilled through cmu wall, replace 7/16" anchor bolt with a 1/2" anchor located at northwest corner of building, add shot pins to to sill plate at 32" o.c., add backing for shower & water closet, provide clarification on whether trusses or rafters are to be used and identify sistering of rafters, missing foam gasket underneath exterior sill plate- see P5/Detail 13 for information. STOPPED INSPECTION-ADDITIONAL ITEMS MY BE NOTED.
10/02/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10.2.25
Corrections made