Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address:
5132 E PIMA ST
Address NEW:
5132 E PIMA ST
Apply Date:
11/20/2024
Applicant:
Jose Garcia
Description:
Repair Fire Damage

Permit Reviews

Permit Number - TC-RES-1124-06768
Permit Status: Issued
Permit Description: Repair Fire Damage
Start Date Submittal Complete Date Status  
11/21/2024 RESIDENTIAL NEW DWELLING v.1 12/27/2024 REQUIRES RESUBMIT Review Details
05/15/2025 RESIDENTIAL NEW DWELLING REVISION v.2 06/17/2025 APPROVED Review Details
02/03/2025 RESIDENTIAL NEW DWELLING v.3 02/05/2025 APPROVED Review Details
01/26/2025 RESIDENTIAL NEW DWELLING v.2 01/27/2025 REQUIRES RESUBMIT Review Details
04/16/2025 RESIDENTIAL NEW DWELLING REVISION v.1 04/16/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1124-06768
Permit Status: Issued
Permit Description: Repair Fire Damage
Total Outstanding Activity Conditions - 1
Date Name
12/10/2024 Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents.

Conditions

Permit Number - TC-RES-1124-06768
Permit Status: Issued
Permit Description: Repair Fire Damage
Date Description Comments
11/21/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-1124-06768
Permite Description: Repair Fire Damage
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
06/10/2025 RSBU - Building Final N/A Re-inspection required 6-10-25: not ready.
06/13/2025 BULD - Electrical Clearance N/A Not Applicable 6-13-25: not applicable
07/15/2025 COT - RSEL - Electrical Final N/A Re-inspection required 7-15-25: missing hammer arrestor at dishwasher, furnace not connected, hallway bathroom fan not working, remove all covers from smoke detectors, bedroom 1 is missing a receptacle,master bedroom is 2 receptacles, and hallway is missing 1 receptacle, panel is missing an updated schedule-water heater not marked, plans call for an a/c 40 amp breaker and you installed a split unit. Either Provide a revision reflecting this or install as per approved plans, pressure relieve valve must be pvc or cpvc, missing electrical cover at laundry room, thermostat must be installed no higher than 48" o.c., exterior receptacles must be weather resistant, insulate hose bibs with r-3 and tape using 10 mil tape. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.
07/15/2025 COT - RSME - Mechanical Final N/A Re-inspection required 7-15-25: missing hammer arrestor at dishwasher, furnace not connected, hallway bathroom fan not working, remove all covers from smoke detectors, bedroom 1 is missing a receptacle,master bedroom is 2 receptacles, and hallway is missing 1 receptacle, panel is missing an updated schedule-water heater not marked, plans call for an a/c 40 amp breaker and you installed a split unit. Either Provide a revision reflecting this or install as per approved plans, pressure relieve valve must be pvc or cpvc, missing electrical cover at laundry room, thermostat must be installed no higher than 48" o.c., exterior receptacles must be weather resistant, insulate hose bibs with r-3 and tape using 10 mil tape. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.
07/15/2025 COT - RSPL - Plumbing Final N/A Re-inspection required 7-15-25: missing hammer arrestor at dishwasher, furnace not connected, hallway bathroom fan not working, remove all covers from smoke detectors, bedroom 1 is missing a receptacle,master bedroom is 2 receptacles, and hallway is missing 1 receptacle, panel is missing an updated schedule-water heater not marked, plans call for an a/c 40 amp breaker and you installed a split unit. Either Provide a revision reflecting this or install as per approved plans, pressure relieve valve must be pvc or cpvc, missing electrical cover at laundry room, thermostat must be installed no higher than 48" o.c., exterior receptacles must be weather resistant, insulate hose bibs with r-3 and tape using 10 mil tape. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-1124-06768
Permit Description: Repair Fire Damage
Total Completed Inspections - 2
Date Description Inspector Results Comments
06/13/2025 BULD - Electrical Clearance Passed 6-13-25: panel okay to be energized. INCR clearance issued to TEP, however, contractor must submit an application to obtain activation.
09/12/2025 COT - BULD - SWG Clearance Passed 9/12/25
SOUTHWEST GAS: SWG

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2024 - 1,300 SQ. FT.- TUCSON PROJECT - JOSE GARCIA - GERONIMO. - SEP.2024 - CHANGES 04-03-25_V1.PDF DOCUMENTS VIEW
DOC14_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2024 - 1300 SQ. FT.- TUCSON PROJECT - JOSE GARCIA - GERONIMO. - REVISION DEC. 26 TH.2024_V1.PDF DOCUMENTS VIEW