Permit: TC-RES-1124-06768
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
5132 E PIMA ST
Address NEW:
5132 E PIMA ST
Apply Date:
11/20/2024
Applicant:
Jose Garcia
Description:
Repair Fire Damage
Permit Reviews
Permit Number - TC-RES-1124-06768
Permit Status: Issued
Permit Description: Repair Fire Damage
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/21/2024 | RESIDENTIAL NEW DWELLING v.1 | 12/27/2024 | REQUIRES RESUBMIT |
| 05/15/2025 | RESIDENTIAL NEW DWELLING REVISION v.2 | 06/17/2025 | APPROVED |
| 02/03/2025 | RESIDENTIAL NEW DWELLING v.3 | 02/05/2025 | APPROVED |
| 01/26/2025 | RESIDENTIAL NEW DWELLING v.2 | 01/27/2025 | REQUIRES RESUBMIT |
| 04/16/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 04/16/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-1124-06768
Permit Status: Issued
Permit Description: Repair Fire Damage
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/10/2024 | Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents. |
Conditions
Permit Number - TC-RES-1124-06768
Permit Status: Issued
Permit Description: Repair Fire Damage
| Date | Description | Comments |
|---|---|---|
| 11/21/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-RES-1124-06768
Permite Description: Repair Fire Damage
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2025 | RSBU - Building Final | N/A | Re-inspection required | 6-10-25: not ready. |
| 06/13/2025 | BULD - Electrical Clearance | N/A | Not Applicable | 6-13-25: not applicable |
| 07/15/2025 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 7-15-25: missing hammer arrestor at dishwasher, furnace not connected, hallway bathroom fan not working, remove all covers from smoke detectors, bedroom 1 is missing a receptacle,master bedroom is 2 receptacles, and hallway is missing 1 receptacle, panel is missing an updated schedule-water heater not marked, plans call for an a/c 40 amp breaker and you installed a split unit. Either Provide a revision reflecting this or install as per approved plans, pressure relieve valve must be pvc or cpvc, missing electrical cover at laundry room, thermostat must be installed no higher than 48" o.c., exterior receptacles must be weather resistant, insulate hose bibs with r-3 and tape using 10 mil tape. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
| 07/15/2025 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 7-15-25: missing hammer arrestor at dishwasher, furnace not connected, hallway bathroom fan not working, remove all covers from smoke detectors, bedroom 1 is missing a receptacle,master bedroom is 2 receptacles, and hallway is missing 1 receptacle, panel is missing an updated schedule-water heater not marked, plans call for an a/c 40 amp breaker and you installed a split unit. Either Provide a revision reflecting this or install as per approved plans, pressure relieve valve must be pvc or cpvc, missing electrical cover at laundry room, thermostat must be installed no higher than 48" o.c., exterior receptacles must be weather resistant, insulate hose bibs with r-3 and tape using 10 mil tape. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
| 07/15/2025 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 7-15-25: missing hammer arrestor at dishwasher, furnace not connected, hallway bathroom fan not working, remove all covers from smoke detectors, bedroom 1 is missing a receptacle,master bedroom is 2 receptacles, and hallway is missing 1 receptacle, panel is missing an updated schedule-water heater not marked, plans call for an a/c 40 amp breaker and you installed a split unit. Either Provide a revision reflecting this or install as per approved plans, pressure relieve valve must be pvc or cpvc, missing electrical cover at laundry room, thermostat must be installed no higher than 48" o.c., exterior receptacles must be weather resistant, insulate hose bibs with r-3 and tape using 10 mil tape. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-RES-1124-06768
Permit Description: Repair Fire Damage
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2025 | BULD - Electrical Clearance | Passed | 6-13-25: panel okay to be energized. INCR clearance issued to TEP, however, contractor must submit an application to obtain activation. | |
| 09/12/2025 | COT - BULD - SWG Clearance | Passed | 9/12/25 SOUTHWEST GAS: SWG |