Permit: TC-RES-1124-06741
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
121 W 17TH ST
Address NEW:
121 W 17TH ST
Apply Date:
11/19/2024
Applicant:
Hailey McGaw
Description:
· NEW FUNCTIONALLY-GROUNDED DC PV SYSTEM · PC ARRAY INSTALLED ON AN ALUMINUM SHADE CANOPY · PV SYSTEM SIZE: 13.2kW DC, 11.38kW AC · PV SYSTEM INTERCONNECTED TO THE UTILITY GRID THROUGH STRUCTURE'S EXISTING ELECTRICAL SERVICE EQUIPMENT (30) APTOS; DNA-144-BF26-440 - 440W MODULES (30) MICRO-INVERTERS; ENPHASE; IQ8H-72-2-US (1) NEW PV ENPAHSE COMBINER PANEL WITH ENPHASE GATEWAY (1) NEW UTILITY DG DISCONNECT (1) NEW DG METER (1) NEW METER SOCKET ADAPTER (1) NEW SHADE CANOPY (INSTALLED BY OTHERS)
Permit Reviews
Permit Number - TC-RES-1124-06741
Permit Status: Inspections
Permit Description: · NEW FUNCTIONALLY-GROUNDED DC PV SYSTEM
· PC ARRAY INSTALLED ON AN ALUMINUM SHADE CANOPY
· PV SYSTEM SIZE: 13.2kW DC, 11.38kW AC
· PV SYSTEM INTERCONNECTED TO THE UTILITY GRID THROUGH STRUCTURE'S EXISTING ELECTRICAL SERVICE EQUIPMENT
(30) APTOS; DNA-144-BF26-440 - 440W MODULES
(30) MICRO-INVERTERS; ENPHASE; IQ8H-72-2-US
(1) NEW PV ENPAHSE COMBINER PANEL WITH ENPHASE GATEWAY
(1) NEW UTILITY DG DISCONNECT
(1) NEW DG METER
(1) NEW METER SOCKET ADAPTER
(1) NEW SHADE CANOPY (INSTALLED BY OTHERS)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/29/2025 | RESIDENTIAL SOLAR v.4 | 06/05/2025 | REQUIRES RESUBMIT |
| 07/22/2025 | RESTAMP - RESIDENTIAL v.1 | 07/23/2025 | APPROVED |
| 11/20/2024 | RESIDENTIAL SOLAR v.1 | 12/27/2024 | REQUIRES RESUBMIT |
| 02/21/2025 | RESIDENTIAL SOLAR v.2 | 02/21/2025 | REQUIRES RESUBMIT |
| 06/12/2025 | RESIDENTIAL SOLAR v.5 | 07/22/2025 | APPROVED |
| 02/23/2025 | RESIDENTIAL SOLAR v.3 | 03/24/2025 | REQUIRES RESUBMIT |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1124-06741
Permit Description: · NEW FUNCTIONALLY-GROUNDED DC PV SYSTEM
· PC ARRAY INSTALLED ON AN ALUMINUM SHADE CANOPY
· PV SYSTEM SIZE: 13.2kW DC, 11.38kW AC
· PV SYSTEM INTERCONNECTED TO THE UTILITY GRID THROUGH STRUCTURE'S EXISTING ELECTRICAL SERVICE EQUIPMENT
(30) APTOS; DNA-144-BF26-440 - 440W MODULES
(30) MICRO-INVERTERS; ENPHASE; IQ8H-72-2-US
(1) NEW PV ENPAHSE COMBINER PANEL WITH ENPHASE GATEWAY
(1) NEW UTILITY DG DISCONNECT
(1) NEW DG METER
(1) NEW METER SOCKET ADAPTER
(1) NEW SHADE CANOPY (INSTALLED BY OTHERS)
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/03/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 9.3.25 Footing depth verified Footer schedule verified F1 and F2 rebar schedules OK TO PROCEED |
|
| 09/03/2025 | COT - RSOL - Grounding/Bonding Solar Project | Passed | 9.3.25 Ground rods verified 6 ft apart Proceed |
|
| 09/08/2025 | COT - RSOL - Electrical Underground Solar Project | Passed | 9.8.2025 Okay to backfill, shading required. |
|
| 09/19/2025 | RSBU - Building Final | Passed | ||
| 09/19/2025 | COT - RSOL - Electrical Final Solar Project | Passed | ||
| 09/19/2025 | BULD - Electrical Clearance | Passed | Approved solar - DGC Clearance to TEP is required for the solar meter |