Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-1124-06741
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/20/2024 | Site Engineering | NOT REQUIRED | |||
| 12/27/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/09/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1124-06741 (121 W 17TH ST TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. Provide a Grounding Electrode System at the detached structures per NEC 690.47. 2. Show the Grounding Conductor’s connection at the modules, mounting and metal support structure. 3. Show grounding details for the mounting equipment and metal support frame, NEC690.43. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/05/2024 | Residential Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please submit the complete set of calculations, prepared by an Arizona licensed design professional, used in the design of the Solar Shade Structure. IBC 107.2.1 A. Design required for resistance to gravity and lateral loads 2. Please amend plans to show the following on the plans and in the calculations. IBC 107.2.1 A. 2018 IBC as amended by the City of Tucson B. Roof Live load and Dead loads C. Wind speed D. Design load-bearing values of soils. E. Risk Category 3. Please amend plans to provide referenced callouts to show all and detail all connections, fasteners, welds bolts, etc., to include the method of connecting the modules to the Solar Shade Structure. IBC 107.2.7 4. Please ensure all sheets used to describe the construction and design of the Solar Shade Structure are sealed by the design professional. Section 107.1, IBC 2018 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 12/27/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando Garcia Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-1124-06741 – Residential Building/Solar Array 121 W 17th St, Tucson, AZ 85701 Plan Review (1st Review) TRANSMITTAL DATE: December 27, 2024 This site is zoned O-3 (UDC Section 4.7.15). An detached single-family dwelling is a permitted use in the O-3 zone. Email the reviewer below directly on resubmittal for faster review. 1. (Comment) In the O-3 zone, setbacks to adjoining properties are 10’ or ¾ the height of the structure’s walls. The proposed setbacks for this structure are 6’ 9” to the west, 6’ 4” to the south, and 6’ 9” to the east. 2. (Comment) Detached structures are permitted to be built to the lot line with neighbor waivers signed by the adjoining property owners. In this case, you would need signed neighbor waivers for the properties at 124th W 18th St, 726 S 7th Av, and 708 S Rubio Av. Provide this waiver language on the next site plan for each neighbor: My name is ______ and I am the owner of the property located at ______. I have reviewed the site plan and I have no objection to the structure being located or construct __ feet from the property line as depicted on the site plan. Signature: ________ Date: _________ 3. (Comment) In case neighbor waivers cannot be obtained, then a Design Development Option (DDO) variance would have to be requested and approved for reduced setbacks. Contact Georgia Pennington at georgia.pennington@tucsonaz.gov for more information about the DDO process and an application. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Updated site plan with detailed comment response letter indicating responses to Site Zoning comments above. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 11/20/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |