Start Date Submittal Complete Date Status  
08/22/2025 RESIDENTIAL NEW DWELLING v.3 08/26/2025 REQUIRES RESUBMIT Review Details
07/22/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/22/2026 APPROVED Review Details
09/11/2025 ADMINISTRATIVE v.1 09/11/2025 REQUIRES RESUBMIT Review Details
09/10/2025 RESIDENTIAL NEW DWELLING v.4 09/10/2025 APPROVED Review Details
09/11/2025 RESTAMP - RESIDENTIAL v.1 09/11/2025 APPROVED Review Details
09/10/2025 RESTAMP - RESIDENTIAL v.1 09/11/2025 APPROVED Review Details
07/22/2025 RESIDENTIAL NEW DWELLING v.2 08/04/2025 REQUIRES RESUBMIT Review Details
11/19/2024 RESIDENTIAL NEW DWELLING v.1 12/20/2024 REQUIRES RESUBMIT Review Details
01/23/2026 ADMINISTRATIVE v.2 01/23/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-1124-06643
Permit Status: Complete
Permit Description: Duplex
Date Description Comments
07/22/2025 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
11/19/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
08/22/2025 Parcel is located within a regulatory floodplain. Engineering review required prior to issuance, floodplain use permit may be required. Grading development package required to be submitted and approved prior to approval of this permit.
12/09/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
12/09/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-1124-06643
Permite Description: Duplex
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
02/19/2026 COT - RSBU - Preslab N/A Re-inspection required (with fee) 2-19-26: SSTB bolts are required before concrete pour using AnchorMate anchor holders. Install per Simpson specifications.
03/04/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 03/04/2026
Add smoke detector in unit 1 hallway near vicinity of bedrooms.
06/24/2026 COT - RSEL - Electrical Final N/A Canceled 06/24/2026
Canceled at contractor request.
07/10/2026 COT - RSEL - Electrical Underground N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-1124-06643
Permit Description: Duplex
Total Completed Inspections - 16
Date Description Inspector Results Comments
02/13/2026 COT - RSPL - Rough Soil Passed Passed 2/13/26, ok to backfill
02/19/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
02/26/2026 COT - RSBU - Roof Nailing Passed 2/26/2026
All corrections made to prior inspection.
02/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 2/26/2026
All corrections made to prior inspection.
03/04/2026 BULD - Electrical Clearance Passed 03/04/2026
Clearance TEP ECO.
03/04/2026 COT - RSEL - Grounding/Bonding Passed 03/04/2026
Tied Ufer to MSP.
03/04/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 03/04/2026
Verified added smoke detector in hallway same day.
03/13/2026 COT - RSBU - Firewall/Fire Barrier/Firestop Passed 3-13-26: drywall screw inspection and fire wall approved. Okay to tape & texture.
05/27/2026 COT - RSPL - Sewer Passed 5/27/2026
Okay to backfill, backwater valve installed.
06/23/2026 COT - RSEL - Outdoor Lighting Passed
06/23/2026 COT - RSPL - Yard Water Line Passed 06/23/2026
Holding under test from meter to riser. Okay to backfill, shading required.
07/08/2026 COT - RSME - Mechanical Final Passed 07/08/2026
Corrections made.
07/08/2026 COT - RSPL - Plumbing Final Passed 07/08/2026
Corrections made.
07/10/2026 COT - RSEL - Electrical Final Passed 07/10/2026
Corrections made.
07/10/2026 RSBU - Building Final Passed
08/05/2026 ENGR Engineering Final Passed Landings comply and DG driveway extends to landings.