Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06643
Parcel: 120080150

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-1124-06643
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/04/2025 Site Zoning APPROVED
08/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/22/2025 Addressing Validation REQUIRES RESUBMIT Thank you for your submission. Please address the following:

1. The Construction Plans [CONS-Site_Plan_02B_v2.pdf] are missing a complete address with unit 1 AND unit 2. Furthermore, pages 3-8 include the incorrect address. Please resubmit plan documents with the address and Unit 1 and 2 on ALL pages to this same permit.
2. 4509 S 7TH AV is not properly addressed with Unit 1 and Unit 2 with Pima County. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to properly address units. Additionally, a sub-records request will be required to change the addresses on the permit.

Allow the full review time to complete this task as there may be other items to be addressed. If you have any questions, please contact us at building_official@tucsonaz.gov.
07/22/2025 Residential Building REQUIRES RESUBMIT TC-RES-1124-06643 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLANS:

1. Provide interior braced wall panels with foundation anchor bolt connection to bottom plates, R602.10.8.3 and R403.1.6. Show an interior braced wall foundation on the Foundation Plan, sheet 3. Also, show the foundation with anchor bolts on section B, sheet 8.

ELECTRICAL PLANS:

1. Update the Riser Diagram showing a single underground service feeder to a dual meter panel, NEC 225.30 and E3403.
2. Show a smoke alarm in each bedroom outside of a closet, R314.3. Include the two-bedroom unit.
3. Update the code reference shown at the top of sheet 5 and within the notes block at the top right corner of the sheet.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
07/22/2025 PDSD Application Completeness Express REVIEW COMPLETED