Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address NEW:
1015 N ANITA AV UNIT 1
Apply Date:
11/01/2024
Applicant:
alex enoch
Description:
Duplex

Permit Reviews

Permit Number - TC-RES-1124-06351
Permit Status: Inspections complete
Permit Description: Duplex
Start Date Submittal Complete Date Status  
11/01/2024 RESIDENTIAL NEW DWELLING v.2 11/01/2024 REQUIRES RESUBMIT Review Details
01/02/2025 RESIDENTIAL NEW DWELLING v.4 01/22/2025 APPROVED Review Details
03/03/2025 RESIDENTIAL NEW DWELLING REVISION v.1 04/03/2025 REQUIRES RESUBMIT Review Details
11/14/2024 RESIDENTIAL NEW DWELLING v.3 12/20/2024 REQUIRES RESUBMIT Review Details
11/01/2024 RESIDENTIAL NEW DWELLING v.1 11/01/2024 REQUIRES RESUBMIT Review Details
04/25/2025 RESIDENTIAL NEW DWELLING REVISION v.2 04/28/2025 APPROVED Review Details
04/28/2025 RESTAMP - RESIDENTIAL v.1 04/29/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1124-06351
Permit Status: Inspections complete
Permit Description: Duplex
Total Outstanding Activity Conditions - 1
Date Name
12/03/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Conditions

Permit Number - TC-RES-1124-06351
Permit Status: Inspections complete
Permit Description: Duplex
Date Description Comments
01/02/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
12/03/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1124-06351
Permite Description: Duplex
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
05/16/2025 COT - RSBU - Preslab N/A Failed
07/02/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 7/2/25

1. All top plate penetrations are missing fire caulk.
2. Main water line needs to be supported inside.
3. Dryer vent is warped.
4. Laundry vent needs boca plates, top and sill. Top safety plate needs to extend minimum 2" below top plate.
5. Laundry is missing Electrical for dryer
6. Stud protectors needed throughout, see "x" on the studs.
7. Bathroom ABS needs boca plates; water lines need boca plates.
8. Flex line for bathroom is kinked/smashed, will need to be rerouted
9. Mortar needed at bathtub drain
10. Missing grey water line at laundry
11. Fix sharp bends in exhaust bends.
12/04/2025 COT - RSEL - Electrical Underground N/A Not Applicable

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1124-06351
Permit Description: Duplex
Total Completed Inspections - 17
Date Description Inspector Results Comments
05/08/2025 COT - RSPL - Rough Soil Passed Ok to cover progress areas.
05/16/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
05/19/2025 COT - RSEL - Grounding/Bonding Passed
06/05/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
06/06/2025 COT - RSBU - Roof Nailing Passed Ok to dry-in roof system.
06/11/2025 COT - RSBU - Preslab Passed Footings for exterior front and back porches approved. Okay for concrete placement. 6/11/2025
07/02/2025 COT - RSPL - Yard Water Line Passed 7/2/25
Pass
07/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Listed items were addressed, corrected and Approved. Okay to cover progress areas of unit #1 and unit #2
07/03/2025 BULD - Electrical Clearance Passed Approved 200A service panels for Duplex - ECO Clearance to TEP is required for Unit #1 and Unit #2
07/31/2025 COT - RSBU - Firewall/Fire Barrier/Firestop Passed Ok to sheet rock throughout
08/06/2025 COT - RSBU - Interior Shear Bracing Passed 8.6.25
Approved
11/12/2025 RSPL - Plumbing Progress Passed Sewer and HCS is OK to cover
12/04/2025 RSBU - Building Final Passed
12/04/2025 COT - RSEL - Electrical Final Passed
12/04/2025 COT - RSME - Mechanical Final Passed
12/04/2025 COT - RSPL - Plumbing Final Passed
12/04/2025 COT - RSEL - Outdoor Lighting Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
PLAN SET V2 REV 1_V2.PDF DOCUMENTS VIEW
CONS-PLAN SET V2_V3.PDF DOCUMENTS VIEW
JOB 00015_V1.PDF DOCUMENTS VIEW
CONS-PLAN SET V2_V3.PDF DOCUMENTS VIEW
JOB 00015_V1.PDF DOCUMENTS VIEW