Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1124-06351
Parcel: 116161530

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING REVISION v.1

Permit Number - TC-RES-1124-06351
Review Name: RESIDENTIAL NEW DWELLING REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/25/2025 Residential Building - Standard APPROVED
03/27/2025 Site Zoning - Standard APPROVED
04/02/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/02/2025 Site Engineering - Standard REQUIRES RESUBMIT TC-RES-1124-06351
1015 N ANITA AV

Site engineering comments are as follows:
This site and the site directly to its north both have duplexes proposed for each lot. No barrier exists between the two lots to prevent vehicular access and maneuverability from being shared between the two lots.
As such, these two lots may be considered a single unified site, and as such – with four dwelling units total between them – would potentially be considered a commercial multifamily site which may require parking improvements, pedestrian circulation, and/or landscaping.
If these two lots are meant to operate independently of each other, demonstrate on the plans how vehicles would be prevented from maneuvering between the two sites. This could be in the form of a perimeter boundary (wall or fence) or curbing of the parking area on the southern lot (1015 N Anita Av).

Ryan Insalaco – ryan.insalaco@tucsonaz.gov
03/03/2025 PDSD Application Completeness Express REVIEW COMPLETED