REV1: Revision per inspector and J8 Manual attachment Internal Fire, smoke damage restoration CE-VIO0625-02590

Permit Reviews

Permit Number - TC-RES-1025-04939
Permit Status: Inspections
Permit Description: REV1: Revision per inspector and J8 Manual attachment Internal Fire, smoke damage restoration CE-VIO0625-02590
Start Date Submittal Complete Date Status  
01/02/2026 RESIDENTIAL NEW DWELLING REVISION v.1 01/02/2026 REQUIRES RESUBMIT Review Details
04/27/2026 RESIDENTIAL ADD/ALT SIMPLE REVIEW REVISION v.1 05/21/2026 APPROVED Review Details
10/13/2025 RESIDENTIAL ADD/ALT v.1 11/07/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-1025-04939
Permit Status: Inspections
Permit Description: REV1: Revision per inspector and J8 Manual attachment Internal Fire, smoke damage restoration CE-VIO0625-02590
Date Description Comments
10/13/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-1025-04939
Permite Description: REV1: Revision per inspector and J8 Manual attachment Internal Fire, smoke damage restoration CE-VIO0625-02590
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
06/05/2026 COT - BULD - SWG Clearance N/A Not Ready
12/11/2025 BULD - Electrical Clearance N/A Re-inspection required 12-11-25: this is a fire damaged house and because many of the existing walls were exposed, therefore, a full set up plans are now required showing work to be done. Submit the plans to city for review/approval.
Note: current set of plans indicate to bring house up to code and to use existing plumbing. However, it appears that new pex is being installed throughout, walls are being furred out and windows have already been replaced. Plans for all work are required.
12/30/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 12/30/25: revised set of plans has been submitted (electrical plan is missing panel schedule with circuit number and wire size, plumbing plan missing in-wall schematic), all penetrations at top plate must be sealed, all existing duct work must be properly sealed, plumbing must be properly supported and all domestic hot water lines 3/4" or larger require R-3 insulation

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-1025-04939
Permit Description: REV1: Revision per inspector and J8 Manual attachment Internal Fire, smoke damage restoration CE-VIO0625-02590
Total Completed Inspections - 1
Date Description Inspector Results Comments
06/18/2026 BULD - Electrical Clearance Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-CONS-5534SCANADA-REV-V3_V2.PDF DOCUMENTS VIEW
DOCS-6820 (CANADA) 5534 S CANADA DR CALCS2 J8-V3_V1.PDF DOCUMENTS VIEW
DOCS_CANADA DR-V3_V2.PDF DOCUMENTS VIEW
20251022_5534_RESTORATION_V1.PDF DOCUMENTS VIEW
CONS-20251009_5534_RESTORATION_V1.PDF DOCUMENTS VIEW