Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address NEW:
934 W CALLE MEDINA
Apply Date:
10/02/2025
Applicant:
Fernando Hinojosa
Description:
REV1: Corrected direction of sewer Remodel SFR and Master Suite Addition

Permit Reviews

Permit Number - TC-RES-1025-04835
Permit Status: Inspections complete
Permit Description: REV1: Corrected direction of sewer Remodel SFR and Master Suite Addition
Start Date Submittal Complete Date Status  
03/25/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/25/2026 APPROVED Review Details
11/28/2025 RESIDENTIAL ADD/ALT v.2 12/01/2025 APPROVED Review Details
10/03/2025 RESIDENTIAL ADD/ALT v.1 10/31/2025 REQUIRES RESUBMIT Review Details
12/01/2025 RESTAMP - RESIDENTIAL v.1 12/03/2025 APPROVED Review Details
12/10/2025 ADMINISTRATIVE v.3 12/10/2025 APPROVED Review Details
12/09/2025 ADMINISTRATIVE v.2 12/09/2025 REQUIRES RESUBMIT Review Details
06/04/2026 RESIDENTIAL NEW DWELLING REVISION v.1 06/10/2026 APPROVED Review Details
12/03/2025 ADMINISTRATIVE v.1 12/03/2025 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-1025-04835
Permit Status: Inspections complete
Permit Description: REV1: Corrected direction of sewer Remodel SFR and Master Suite Addition
Date Description Comments
10/03/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
10/21/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1025-04835
Permite Description: REV1: Corrected direction of sewer Remodel SFR and Master Suite Addition
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
10/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass 10-26-26 Pending verification on post to beam connection reinspect
10/26/2026 COT - RSPL - Plumbing Final N/A Re-inspection required
10/26/2026 COT - RSEL - Electrical Final N/A Re-inspection required 10-26-26 High waterloop under kitchen sink going to dishwasher should be mounted at its highest point* hammer arrestor missing at hot water going to dishwasher* provide hammer arresters at washing machine inlet* window at shower in master bathroom is required to be tamper glass, provide specs for proof* All exterior receptacles are to be GFCI protected as well as WR approved* correctly fasten electrical box on back porch-right of electrical panel at North west corner* Provide tall enough ladder for roof access to properly inspect condensing unit* reinspection is required at this time. More items may be added
10/26/2026 RSBU - Building Final N/A Re-inspection required 10-26-26 High waterloop under kitchen sink going to dishwasher should be mounted at its highest point* hammer arrestor missing at hot water going to dishwasher* provide hammer arresters at washing machine inlet* window at shower in master bathroom is required to be tamper glass, provide specs for proof* All exterior receptacles are to be GFCI protected as well as WR approved* correctly fasten electrical box on back porch-right of electrical panel at North west corner* Provide tall enough ladder for roof access to properly inspect condensing unit* reinspection is required at this time. More items may be added
10/26/2026 COT - RSME - Mechanical Final N/A Re-inspection required 10-26-26 High waterloop under kitchen sink going to dishwasher should be mounted at its highest point* hammer arrestor missing at hot water going to dishwasher* provide hammer arresters at washing machine inlet* window at shower in master bathroom is required to be tamper glass, provide specs for proof* All exterior receptacles are to be GFCI protected as well as WR approved* correctly fasten electrical box on back porch-right of electrical panel at North west corner* Provide tall enough ladder for roof access to properly inspect condensing unit* reinspection is required at this time. More items may be added

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1025-04835
Permit Description: REV1: Corrected direction of sewer Remodel SFR and Master Suite Addition
Total Completed Inspections - 13
Date Description Inspector Results Comments
05/05/2026 COT - RSBU - Preslab Passed 5.5.26 approved
05/05/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 5.5.26 approved
06/02/2026 COT - RSBU - Roof Nailing Passed
07/08/2026 COT - RSPL - Gas Pressure Test Passed
07/10/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 07/10/2026
Corrections made.
08/04/2026 COT - RSBU - Interior Shear Bracing Passed 08/04/2026
Verified drywall nailing scheduled. Okay to tape & texture.
10/26/2026 COT - RSPL - Rough Soil Passed 10-26-26 revision updated OK to proceed
10/28/2026 COT - RSEL - Outdoor Lighting Passed
10/28/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 10/28/2026
All corrections made. Verified designer change on beam/post connection.
10/28/2026 COT - RSPL - Plumbing Final Passed 10/28/2026
All corrections made.
10/28/2026 COT - RSEL - Electrical Final Passed 10/28/2026
All corrections made. Verified roof mechanical equipment.
10/28/2026 RSBU - Building Final Passed 10/28/2026
All corrections made. Conditions satisfied.
10/28/2026 COT - RSME - Mechanical Final Passed 10/28/2026
All corrections made. Verified roof mechanical equipment.

Documents

File Name Document Type  
ALMADER 934 REVISION NARRATIVE 26-0601_V1.PDF DOCUMENTS VIEW
CONS-ALMADER 934 26-0601 PERMIT SET REV 1_V1.PDF DOCUMENTS VIEW
ALMADER 934-LAYOUT_V1.PDF DOCUMENTS VIEW
TC-RES-1025-04835 TRUSS CALCULATION_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
OWNER-BUILDER-AFFIDAVIT_073025_FILLABLE_V2.PDF DOCUMENTS VIEW
CONS-ALMADER 934 25-1124 PERMIT SET_V2.PDF DOCUMENTS VIEW