Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 07/08/2026 Add Boca plate to bottom and top plate for ABS with 1.25" to face, ground metal receptacle boxes, shower liner needs to under test at intermediates, insulate all 3/4" PEX line with r3, missing receptacle in bedroom within 6’of door, missing smoke detector in hallway ear bedrooms. NOTE: Stopped inspection, more items may be noted. |
|
| 07/10/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 07/10/2026 Corrections made. |