Permit: TC-RES-1023-08507
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3521 S 8TH AV
Address NEW:
3521 S 8TH AV
Apply Date:
10/03/2023
Applicant:
Brad Leto
Description:
Fire Damage Repair
Permit Reviews
Permit Number - TC-RES-1023-08507
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/06/2023 | RESIDENTIAL NEW DWELLING v.1 | 10/23/2023 | APPROVED |
| 01/18/2024 | RESIDENTIAL NEW DWELLING v.1 | 02/02/2024 | APPROVED |
| 03/27/2024 | RESIDENTIAL NEW DWELLING v.1 | 04/29/2024 | REQUIRES RESUBMIT |
| 04/30/2024 | RESIDENTIAL NEW DWELLING v.2 | 06/04/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-1023-08507
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/23/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-1023-08507
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
| Date | Description | Comments |
|---|---|---|
| 02/12/2024 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 02/06/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1023-08507
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/07/2024 | BULD - Electrical Clearance | N/A | Not Ready | |
| 02/07/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Not Ready | |
| 02/07/2024 | COT - RSEL - Grounding/Bonding | N/A | Not Ready | |
| 06/05/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 06/05/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 02/07/2024 | COT - RSEL - Electrical Final | N/A | Not Ready |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1023-08507
Permit Description: Fire Damage Repair
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/02/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 01/02/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 01/31/2024 | COT - RSBU - Preslab | Passed | 1/31/24: reinforcement per plan at slab on east side of house. | |
| 01/31/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 1/31/24: reinforcement per plan at slab on east side of house. | |
| 02/12/2024 | BULD - Electrical Clearance | Passed | ||
| 04/11/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 3/8/24: Not ready. Revision needed on changes made. Blocking required on three sides of A/C supply registers, R-8 flex required in attic (R-6 installed throughout). Electrical not complete. Seal all penetrations through top plate throughout. 4/11/24: corrections made |
|
| 06/03/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 06/05/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 06/06/2024 | COT - RSME - Mechanical Final | Passed | ||
| 06/06/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 06/20/2024 | RSBU - Building Final | Passed | Gfi required for washing machine, smoke detectors are not working properly 6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout, 6/6/24: circuits at panel cannot double tap on a single pole breaker. Revision will be needed to add new panel or sub-panel. 6/20/24: corrections made |
|
| 06/20/2024 | COT - RSEL - Electrical Final | Passed |