Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3521 S 8TH AV
Address NEW:
3521 S 8TH AV
Apply Date:
10/03/2023
Applicant:
Brad Leto
Description:
Fire Damage Repair

Permit Reviews

Permit Number - TC-RES-1023-08507
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
Start Date Submittal Complete Date Status  
10/06/2023 RESIDENTIAL NEW DWELLING v.1 10/23/2023 APPROVED Review Details
01/18/2024 RESIDENTIAL NEW DWELLING v.1 02/02/2024 APPROVED Review Details
03/27/2024 RESIDENTIAL NEW DWELLING v.1 04/29/2024 REQUIRES RESUBMIT Review Details
04/30/2024 RESIDENTIAL NEW DWELLING v.2 06/04/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-1023-08507
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
Total Outstanding Activity Conditions - 1
Date Name
10/23/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-1023-08507
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
Date Description Comments
02/12/2024 The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account.
02/06/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1023-08507
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
02/07/2024 BULD - Electrical Clearance N/A Not Ready
02/07/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready
02/07/2024 COT - RSEL - Grounding/Bonding N/A Not Ready
06/05/2024 COT - BULD - SWG Clearance N/A Not Applicable
06/05/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable
02/07/2024 COT - RSEL - Electrical Final N/A Not Ready

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-1023-08507
Permit Description: Fire Damage Repair
Total Completed Inspections - 12
Date Description Inspector Results Comments
01/02/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
01/02/2024 COT - RSBU - Roof Nailing Passed
01/31/2024 COT - RSBU - Preslab Passed 1/31/24: reinforcement per plan at slab on east side of house.
01/31/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 1/31/24: reinforcement per plan at slab on east side of house.
02/12/2024 BULD - Electrical Clearance Passed
04/11/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3/8/24: Not ready. Revision needed on changes made. Blocking required on three sides of A/C supply registers, R-8 flex required in attic (R-6 installed throughout). Electrical not complete. Seal all penetrations through top plate throughout.
4/11/24: corrections made
06/03/2024 COT - RSEL - Grounding/Bonding Passed
06/05/2024 COT - RSEL - Outdoor Lighting Passed
06/06/2024 COT - RSME - Mechanical Final Passed
06/06/2024 COT - RSPL - Plumbing Final Passed
06/20/2024 RSBU - Building Final Passed Gfi required for washing machine, smoke detectors are not working properly
6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout,
6/6/24: circuits at panel cannot double tap on a single pole breaker. Revision will be needed to add new panel or sub-panel.
6/20/24: corrections made
06/20/2024 COT - RSEL - Electrical Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
59.2023_REVISION LETTER_V2.PDF DOCUMENTS VIEW
CONS-4_PLANS_2023.59_FLORES RESIDENCE_V2.PDF DOCUMENTS VIEW
59.2023_REVISION LETTER_V1.PDF DOCUMENTS VIEW
CONS-2_PLANS_2023.59_FLORES RESIDENCE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-1_PLANS_2023.59 FLORES RESIDENCE_V1.PDF DOCUMENTS VIEW