Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-1023-08507

Parcel: 11904032A


Addresses:

3521 S 8TH AV

Inspection Status: Not Ready

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
02/07/2024 COT - RSEL - Electrical Final  Not Ready
02/12/2024 COT - RSEL - Electrical Final  Not Ready
06/03/2024 COT - RSEL - Electrical Final  Partial Pass
06/05/2024 COT - RSEL - Electrical Final  Re-inspection required Gfi required for washing machine, smoke detectors are not working properly
6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout,
06/06/2024 COT - RSEL - Electrical Final  Re-inspection required Gfi required for washing machine, smoke detectors are not working properly
6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout,
6/6/24: circuits at panel cannot double tap on a single pole breaker. Revision will be needed to add new panel or sub-panel.
06/11/2024 COT - RSEL - Electrical Final  Not Ready Not ready per previous notes. 6/11/2024
06/20/2024 COT - RSEL - Electrical Final  Passed