Permit: TC-RES-1023-08507

Parcel: 11904032A


Addresses:

3521 S 8TH AV

Inspection Status: Partial Pass

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
06/03/2024 RSBU - Building Final  Partial Pass
06/05/2024 RSBU - Building Final  Re-inspection required Install stove and cabinets, open crawl space access to 30 x22
Gfi required for washing machine, smoke detectors are not working properly
6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout,
06/06/2024 RSBU - Building Final  Re-inspection required Gfi required for washing machine, smoke detectors are not working properly
6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout,
6/6/24: circuits at panel cannot double tap on a single pole breaker. Revision will be needed to add new panel or sub-panel.
06/20/2024 RSBU - Building Final  Passed Gfi required for washing machine, smoke detectors are not working properly
6/5/24: water heater missing sediment trap, b-vent requires 1" clearance from combustibles, WR receptacles missing at outdoor receptacles, properly secure whip at ac unit, arc fault breaker's missing throughout,
6/6/24: circuits at panel cannot double tap on a single pole breaker. Revision will be needed to add new panel or sub-panel.
6/20/24: corrections made