Permit: TC-RES-0925-04697
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2132 W WINDOW ROCK DR
Address NEW:
2132 W WINDOW ROCK DR
Apply Date:
09/24/2025
Applicant:
Ricardo Molina
Description:
We are applying for a " After the fact" Permit. We have replaced a 5 ton gas package unit with a 5 Ton Heat Pump. Rev1 House value - $360k - $380k work value - $9,375
Permit Reviews
Permit Number - TC-RES-0925-04697
Permit Status: Inspections
Permit Description: We are applying for a " After the fact" Permit. We have replaced a 5 ton gas package unit with a 5 Ton Heat Pump. Rev1
House value - $360k - $380k
work value - $9,375
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/26/2025 | RESIDENTIAL SIMPLE REVIEW v.2 | 09/29/2025 | APPROVED |
| 09/24/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 09/24/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0925-04697
Permit Status: Inspections
Permit Description: We are applying for a " After the fact" Permit. We have replaced a 5 ton gas package unit with a 5 Ton Heat Pump. Rev1
House value - $360k - $380k
work value - $9,375
| Date | Description | Comments |
|---|---|---|
| 09/24/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0925-04697
Permite Description: We are applying for a " After the fact" Permit. We have replaced a 5 ton gas package unit with a 5 Ton Heat Pump. Rev1
House value - $360k - $380k
work value - $9,375
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 12/10/2025 | COT - RSPL - Plumbing Final | N/A | Not Applicable | 12/10/25 N.A. The mechanical inspection is the only one needed. |
| 12/10/2025 | COT - RSEL - Electrical Final | N/A | Not Applicable | 12/10/25 N.A. The mechanical inspection is the only one needed. |
| 12/10/2025 | COT - RSME - Mechanical Final | N/A | Re-inspection required | junior flex does not have a sun shield that is close enough to do its job to the junior flex. Unit appears to have a leak underneath the unit. The stand supporting the unit should not be located on the eve of the roof and. If no heat strips are installed please mark it in the appropriate spot on the data tag. 12/10/25 1. The unit is missing screws on some of the panels. 2. Condensation line needs to be painted to prevent sun damage 3. Duct transition is torn and not sealed properly underneath. 4. There is a T-stat wire in the control cabinet that is exposed and should be capped. 5. Double check the placement of Unit stand appears to be too close to Eve; have a structural engineer approve the location. 6. Annotate appropriate check box on data plate for heat strips. 7. Attach both liquid tight lines to red wood and keep off roof membrane. |