| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/24/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/24/2025 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | PDSD Residential Review Section PROJECT: TC-RES-0925-04697 Replaced a 5 ton gas package unit with a 5 Ton Heat Pump-(1st Review) (2132 W WINDOW ROCK DR) TRANSMITTAL DATE: September 24th, 2025 Comments:1. Please submit a completed AC Installation Template. A copy of the template can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/air_conditioning_template.pdf 2. Please resubmit a site plan or aerial photograph showing the location of the installed equipment and electrical. 3. Please provide electrical load calculations used in determining that the service panel can support the additional electrical load, E3602.2 and an electrical panel schedule showing wire size and OCPD of each new circuit, E3702.2. 4. Please resubmit the Manual-J. Please email any questions to: Building_Official@tucsonaz.gov |
||
| 09/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |