Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
530 N WILSON AV
Address NEW:
530 N WILSON AV
Apply Date:
09/21/2023
Applicant:
David Berwick
Description:
SFR with Garage

Permit Reviews

Permit Number - TC-RES-0923-08235
Permit Status: Inspections complete
Permit Description: SFR with Garage
Start Date Submittal Complete Date Status  
09/25/2023 RESIDENTIAL NEW DWELLING v.1 10/13/2023 REQUIRES RESUBMIT Review Details
02/15/2024 RESIDENTIAL NEW DWELLING v.3 03/18/2024 APPROVED Review Details
03/18/2024 RESTAMP - RESIDENTIAL v.1 03/25/2024 APPROVED Review Details
10/30/2023 RESIDENTIAL NEW DWELLING v.2 12/06/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0923-08235
Permit Status: Inspections complete
Permit Description: SFR with Garage
Total Outstanding Activity Conditions - 1
Date Name
04/29/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0923-08235
Permit Status: Inspections complete
Permit Description: SFR with Garage
Date Description Comments
03/25/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
10/12/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0923-08235
Permite Description: SFR with Garage
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
09/03/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Not Ready 9/3/24: not ready
11/27/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Secure gas lines in place. Pex lines need to be 12" away from any can lights. Secure pex lines every 32" horizontal. Block registers on three sides. Plans call for double switch in laundry room. Missing 220 for dryer, missing exhaust fan in laundry room. Provide transition glue from abs pipe to pvc in laundry room for grey water. STOPPED INSPECTION. Too many errors. Other items may occur. 11/27/2024
05/08/2025 COT - RSEL - Electrical Underground N/A Not Applicable
11/27/2024 COT - RSPL - Gas Pressure Test N/A Re-inspection required Provide 15 psi at gas gage. 11/27/2024

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0923-08235
Permit Description: SFR with Garage
Total Completed Inspections - 19
Date Description Inspector Results Comments
05/01/2024 COT - RSPL - Sewer Passed
06/17/2024 COT - RSBU - Preslab Passed Ensure slab is termite treated. Ok to place concrete in slab and footings
06/27/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
09/09/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Ok to cover exterior walls
09/09/2024 COT - RSBU - Roof Nailing Passed OK to dry-in roof system
09/09/2024 COT - RSBU - Interior Shear Bracing Passed
09/17/2024 BULD - Electrical Clearance Passed CLEAR ECO for new SFR.
05/08/2025 COT - BULD - SWG Clearance Passed Duplicate inspection. 5/8/2025
05/08/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Duplicate inspection. 5/8/2025
05/08/2025 COT - RSBU - Stem Wall/Retaining Wall Passed
05/08/2025 COT - RSEL - Electrical Final Passed
05/08/2025 COT - RSEL - Grounding/Bonding Passed
05/08/2025 COT - RSEL - Outdoor Lighting Passed
05/08/2025 COT - RSME - Mechanical Final Passed
05/08/2025 COT - RSPL - Gas Pressure Test Passed Duplicate inspection. 5/8/2025
05/08/2025 COT - RSPL - Yard Water Line Passed
05/08/2025 COT - RSPL - Plumbing Final Passed
05/08/2025 COT - RSPL - Rough Soil Passed Duplicate inspection. 5/8/2025
05/08/2025 RSBU - Building Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
PDSD_OWNER_BUILDER_AFFIDAVIT_081623_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
24018 MJ_V1.PDF DOCUMENTS VIEW
CONS-WILSON-DRAWINGS_V2.PDF DOCUMENTS VIEW
DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO APPLICATION AND PLANS.PDF SPECIAL APPLICATIONS VIEW
DDO NOTICE AND MAP.PDF SPECIAL APPLICATIONS VIEW