Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
1252 S SAN ANTONIO DR
Apply Date:
08/26/2024
Applicant:
Maria Robles
Description:
Flex; Laundry and Two Bedroom Addition

Permit Reviews

Permit Number - TC-RES-0824-04955
Permit Status: Inspections
Permit Description: Flex; Laundry and Two Bedroom Addition
Start Date Submittal Complete Date Status  
08/26/2024 RESIDENTIAL NEW DWELLING v.1 09/27/2024 APPROVED Review Details

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0824-04955
Permite Description: Flex; Laundry and Two Bedroom Addition
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
03/26/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 3-26-25, add anchor bolts to marked locations together with shot pins throughout. Add nails to exterior sheathing along edges at marked areas & nails where over penetrated (no more than 1/16 of an inch). Add nails to loose roof panels at marked locations and provide a ladder on reinspect to properly inspect sheathing above.
03/26/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 3-26-25, add anchor bolts to marked locations together with shot pins throughout. Add nails to exterior sheathing along edges at marked areas & nails where over penetrated (no more than 1/16 of an inch). Add nails to loose roof panels at marked locations and provide a ladder on reinspect to properly inspect sheathing above.
08/29/2025 RSBU - Building Final N/A Partial Pass 8-29-25: drywall nailing approved-okay for tape & texture. Add or relocate receptacle to where it is not spaced more than 12' apart (middle bedroom). Install all receptacle covers, plumbing fixtures, exterior lights, etc..and schedule finals when ready.
12/04/2024 COT - RSPL - Plumbing Final N/A Partial Pass Sewer line from new addition area to main sewer. Ok to cover progress area.
08/29/2025 COT - RSME - Mechanical Final N/A Not Ready 8-29-25: not ready.
08/29/2025 COT - RSEL - Outdoor Lighting N/A Not Ready 8-29-25: not ready.
08/29/2025 COT - RSEL - Grounding/Bonding N/A Not Ready 8-29-25: not ready.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0824-04955
Permit Description: Flex; Laundry and Two Bedroom Addition
Total Completed Inspections - 13
Date Description Inspector Results Comments
12/19/2024 COT - RSBU - Preslab Passed 12/19/24: reinforcement per plan ok to proceed with concrete pour
12/19/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 12/19/24: reinforcement per plan ok to proceed with concrete pour
03/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3/28/25 corrections made ok to proceed
03/28/2025 COT - RSBU - Roof Nailing Passed 3/28/25 corrections made ok to proceed
04/02/2025 BULD - Electrical Clearance Passed 4/2/25:TEP INCR CLEARANCE FOR 1252 S SAN ANTONIO DR
06/30/2025 COT - RSEL - Electrical Underground Passed
06/30/2025 COT - RSPL - Rough Soil Passed
07/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 7/3/25
pass
07/21/2026 RSBU - Building Final Passed 07/21/2026
Corrections made to prior inspection.
07/21/2026 COT - RSPL - Plumbing Final Passed
07/21/2026 COT - RSME - Mechanical Final Passed
07/21/2026 COT - RSEL - Outdoor Lighting Passed
07/21/2026 COT - RSEL - Grounding/Bonding Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-COHN_ADDITION_PLANS_FINAL_V1.PDF DOCUMENTS VIEW
PDSD_OWNER_BUILDER_AFFIDAVIT_081623 (1)_V1.PDF DOCUMENTS VIEW