Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/26/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3-26-25, add anchor bolts to marked locations together with shot pins throughout. Add nails to exterior sheathing along edges at marked areas & nails where over penetrated (no more than 1/16 of an inch). Add nails to loose roof panels at marked locations and provide a ladder on reinspect to properly inspect sheathing above.
03/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3/28/25 corrections made ok to proceed