Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address NEW:
10421 E CALLE TRECE
Apply Date:
08/06/2024
Applicant:
Greg Mason
Description:
SFR replacement for demo unit TC-DMO-0224-00020

Permit Reviews

Permit Number - TC-RES-0824-04574
Permit Status: Issued
Permit Description: SFR replacement for demo unit TC-DMO-0224-00020
Start Date Submittal Complete Date Status  
08/06/2024 RESIDENTIAL NEW DWELLING v.1 09/11/2024 REQUIRES RESUBMIT Review Details
02/03/2025 RESIDENTIAL NEW DWELLING REVISION v.2 03/10/2025 APPROVED Review Details
01/15/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/21/2025 APPROVED Review Details
10/07/2024 RESIDENTIAL NEW DWELLING v.2 10/29/2024 APPROVED Review Details
01/30/2025 RESIDENTIAL NEW DWELLING REVISION v.1 01/31/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0824-04574
Permit Status: Issued
Permit Description: SFR replacement for demo unit TC-DMO-0224-00020
Total Outstanding Activity Conditions - 1
Date Name
08/14/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0824-04574
Permit Status: Issued
Permit Description: SFR replacement for demo unit TC-DMO-0224-00020
Date Description Comments
10/07/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-RES-0824-04574
Permite Description: SFR replacement for demo unit TC-DMO-0224-00020
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
02/19/2025 COT - RSBU - Interior Shear Bracing N/A Not Applicable Not Applicable, no interior shear walls.
04/01/2025 COT - RSEL - Outdoor Lighting N/A Canceled Canceled
03/13/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 3/13/25: lath must complete for residential intermediate inspection, seal all penetrations through top plate and vapor barrier, DWV must be under test, straps required midway at DWV in wall. STOPPED INSPECTION PLEASE CALL BACK AFTER LATH IS COMPLETE. MORE ITEMS MAY BE ADDED

Completed Inspections

Permit Status: Issued
Permit Number: TC-RES-0824-04574
Permit Description: SFR replacement for demo unit TC-DMO-0224-00020
Total Completed Inspections - 12
Date Description Inspector Results Comments
01/14/2025 COT - RSPL - Rough Soil Passed 1-14-25, underground plumbing verified as per approved plans. Okay to backfill-provide shading.When ready schedule HCS connection and water line.
01/31/2025 COT - RSBU - Preslab Passed 1-31-25, excavation/rebar layout, preslab for front & back porch areas verified as per approved plans. Okay to pour concrete.
01/31/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 1-31-25, excavation/rebar layout, preslab for front & back porch areas verified as per approved plans. Okay to pour concrete.
02/19/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Okay to dry-in roof, exterior walls, and begin rough-in of mechanical, electrical, and plumbing.
02/19/2025 COT - RSBU - Roof Nailing Passed Okay to dry-in roof, exterior walls, and begin rough-in of mechanical, electrical, and plumbing.
03/13/2025 COT - RSEL - Electrical Underground Passed
03/13/2025 COT - RSPL - Gas Pressure Test Passed
03/14/2025 COT - RSPL - Yard Water Line Passed Passed 3/14/25 ok to backfill
03/14/2025 BULD - Electrical Clearance Passed Ready for temp power CLEARANCE ECO 3/14/25
04/01/2025 COT - RSEL - Grounding/Bonding Passed Passed and covered
04/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 4/3/25 Corrections made
05/12/2025 COT - BULD - SWG Clearance Passed Passed 5/6/25 CLEARANCE SWG

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OWNER_BUILDERAFFIDAVIT_MASON RESIDENT_V1.PDF DOCUMENTS VIEW
TRUSS CALCULATIONS AND LAYOUT MASON RSIDENCE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-D_V2.PDF_V2.PDF DOCUMENTS VIEW