Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0824-04574
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2024 | Site Engineering | NOT REQUIRED | |||
| 09/09/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/06/2024 | Fire New Construction | REQUIRES RESUBMIT | This project requires a fire flow of 1,750 for two hours, IFC Appendix B, Table B105.1(2). Provide fire sprinklers or add additional hydrant to meet fire flow. Questions: patricia.shelton@tucsonaz.gov |
||
| 08/14/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0824-04574 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Provide a response letter on separate file with submitting the updated construction plan set. GENERAL COMMENTS : 1. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a second clothes washer standpipe plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations 2. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space. PLANS: 1. Show the location of each shear wall panel location on sheet S101, R106.1.1. 2. Show braced wall panel compliance for (narrow) framed walls with a garage door opening, Table R602.10.5. For prescriptive braced wall structures show a portal frame with hold-downs PFH method, Figure R602.10.6.2, or a portal frame at garage door PFG method, Figure R602.10.6.3, or a continuously sheathed portal frame CS-PF method, Figure R602.10.6.4 or show a performance solution. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. A two- or three-bedroom dwelling greater than 1500 SF requires a 60 CFM continuous setting. ELECTRICAL PLANS: 1. Clarify the description of circuit #30/32. 2. Provide the Electric Vehicle Supply Equipment 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/09/2024 | Site Landscape | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: SFR REPLACEMENT FOR DEMO UNIT ACTIVITY NO: TC-RES-0824-04574 ADDRESS/PARCEL: 10421 E CALLE TRECE ZONING: RX-1 RESIDENCE ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Ensure that Zoning comments are addressed prior to landscape section approval. 2. Lot 122 was platted prior to 1997, so a traditional NPPO is not required. The plan does show native vegetation set aside on the east, southeast section of the site. Providing the Native Undisturbed Open Space quantification on the cover sheet would be appreciated by Site Landscape/NPPO with your next submittal. ERZ AND RIPARIAN HABITAT COMMENTS: The site is also within the Environmental Resource Zone (ERZ) and the Coronado Ridge Wash and may require additional documentation: See ERZ requirements, Section 5.7.3 Development Options: 3. It appears that no part of the development is encroaching on the Riparian/Floodplain Area - See Option A) No encroachment on the floodplain -- Where the owner of a lot or parcel affected by these standards chooses to leave the 100-year floodplain undisturbed, the ERZ does not apply except that temporary fencing shall be placed between the project site and the floodplain area as provided in Section 5.7.5.B, Temporary Fencing Required. Please provide reference to the protective temporary fencing graphically and with a call out either on the cover sheet or add another sheet for the ERZ and Riparian Habitat information. If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov, or at 520.837.4923 |
||
| 09/03/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0824-04574 10421 E CALLE TRECE – RX-1 New SFR (1st Review) TRANSMITTAL DATE: September 3, 2024 This comment was not addressed. COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the RX-1 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-1). See Use-Specific Standards 4.9.7.B.6. 1. The maximum building height provided on the plan, 25’ is not correct and should be 30’ (UDC Table 6.3-1.A). 2. Remove the reference to “MAXIJMUM LOT COVERAGE = 70%” from the plan as lot coverage is not applicable in the RX-1 zone (UDC Table 6.3-1.A). 3. The street setback line references “20’ SIDE SETBACK” and should reference street setback. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/06/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |