Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
3693 S CAMINO SECO
Apply Date:
08/07/2023
Applicant:
Francisco Lizarraga
Description:
SFR

Permit Reviews

Permit Number - TC-RES-0823-07112
Permit Status: Complete
Permit Description: SFR
Start Date Submittal Complete Date Status  
12/15/2023 RESIDENTIAL NEW DWELLING v.3 12/28/2023 REQUIRES RESUBMIT Review Details
03/27/2024 RESTAMP - RESIDENTIAL v.1 04/01/2024 APPROVED Review Details
01/22/2024 RESIDENTIAL NEW DWELLING v.4 02/05/2024 REQUIRES RESUBMIT Review Details
08/11/2023 RESIDENTIAL NEW DWELLING v.1 08/28/2023 REQUIRES RESUBMIT Review Details
02/26/2024 RESIDENTIAL NEW DWELLING v.5 03/27/2024 APPROVED Review Details
06/26/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/01/2025 APPROVED Review Details
09/26/2023 RESIDENTIAL NEW DWELLING v.2 09/26/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0823-07112
Permit Status: Complete
Permit Description: SFR
Date Description Comments
03/27/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
08/28/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/20/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0823-07112
Permite Description: SFR
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/14/2024 COT - RSEL - Grounding/Bonding N/A Re-inspection required 10/14/24: Install second ground rod and connect copper grounding wire
10/14/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 10/14/24: register needs to be blocked in back hallway. DWV not under test. Tub not under test. All top plate penetrations need to be sealed. Anchor bolts needed at break in plates and within 12 inches of end of plate. Duct work needs to be supported and strapped throughout. Stopped inspection.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0823-07112
Permit Description: SFR
Total Completed Inspections - 18
Date Description Inspector Results Comments
09/05/2024 COT - RSPL - Rough Soil Passed 9/4/24: Entire underground plumbing is under a water test from backwater valve to last fixture in system.
09/05/2024 COT - RSPL - Backwater Valve Passed 9/4/24: Entire underground plumbing is under a water test from backwater valve to last fixture in system.
09/06/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
09/06/2024 COT - RSBU - Preslab Passed
09/27/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
09/27/2024 COT - RSBU - Roof Nailing Passed
10/15/2024 COT - RSEL - Electrical Underground Passed
10/15/2024 COT - RSEL - Grounding/Bonding Passed
10/25/2024 COT - RSBU - Interior Shear Bracing Passed Drywall on interior shear walls is properly nailed to studs per plan requirements. Okay to proceed with tape, texture, and paint of all walls and ceilings.
04/02/2025 BULD - Electrical Clearance Passed Approved new 200A service panel - ECO Clearance is required
06/20/2025 COT - RSEL - Outdoor Lighting Passed Per Ralph 9/24/24 all piping underground passed
06/20/2025 COT - RSPL - Yard Water Line Passed Per Ralph 9/24/24 all piping underground passed
06/20/2025 COT - RSPL - Sewer Passed Per Ralph 9/24/24 all piping underground passed
06/25/2025 RSBU - Building Final Passed 6/25/25 corrections made
06/25/2025 COT - RSME - Mechanical Final Passed 6/25/25 corrections made
06/25/2025 COT - RSEL - Electrical Final Passed 6/25/25 corrections made
06/25/2025 COT - RSPL - Plumbing Final Passed 6/25/25 corrections made
06/25/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed duplicate inspection

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
TRUSS CALCS ROMERO_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-240214 TC-RES-0823-07112 ROMERO (1)_V6.PDF DOCUMENTS VIEW