Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
7215 E STELLA RD
Address NEW:
7215 E STELLA RD
Apply Date:
07/16/2026
Applicant:
BARRY SOPHER
Description:
Family Room, Bedroom and Porch without permit

Permit Reviews

Permit Number - TC-RES-0726-03957
Permit Status: Inspections
Permit Description: Family Room, Bedroom and Porch without permit
Start Date Submittal Complete Date Status  
07/22/2026 RESIDENTIAL ADD/ALT v.1 07/28/2026 REQUIRES RESUBMIT Review Details
08/05/2026 RESIDENTIAL ADD/ALT v.2 N/A REQUIRES RESUBMIT Review Details
08/13/2026 RESIDENTIAL ADD/ALT v.3 08/14/2026 APPROVED Review Details

Conditions

Permit Number - TC-RES-0726-03957
Permit Status: Inspections
Permit Description: Family Room, Bedroom and Porch without permit
Date Description Comments
08/14/2026 Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0726-03957
Permite Description: Family Room, Bedroom and Porch without permit
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/15/2026 PDSD Building Division SIte Consultation N/A Re-inspection required 9/15/26 – Inspection Corrections
All work was completed and closed out prior to the required inspections being performed. The following items shall be exposed and verified:

Framing, electrical, and footing/slab: Work shall be exposed as necessary to verify compliance with the approved plans and applicable code requirements.

Bedroom electrical spacing: The electrical spacing in the bedroom does not comply with code and shall be corrected.

Bedroom window: The window shall be installed in accordance with the approved plans, including the required size.

Weep screed: The weep screed has been improperly installed and shall be corrected.

Footings: Footings shall be exposed at multiple locations to verify the required footing depth.

Slab and footing reinforcement: A qualified third-party agency shall perform X-ray/scanning of the slab and footings to verify the location and adequacy of reinforcement.

Sole plate: The sole plate shall be exposed to verify proper anchorage and confirm that a treated sole plate was used where required.

Top plate and vapor barrier penetrations: Penetrations through the top plate and vapor barrier shall be exposed and verified. All required penetrations shall be properly sealed.

All corrections and required exposure shall be completed and made available for verification prior to approval of the work.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-MERGED 07302026.2-7215-STELLA-RD_V2.PDF DOCUMENTS VIEW
RECEIPT_05-08-2026_18-52-04-C1_V1.PDF DOCUMENTS VIEW
RESPONSE LETTER (1)-2026-08-02_V1.PDF DOCUMENTS VIEW