Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3256 N INCAS AV
Address NEW:
3256 N INCAS AV
Apply Date:
07/08/2025
Applicant:
Sue Wilson
Description:
Interior hot & cold repipe of the domestic water distribution system

Permit Reviews

Permit Number - TC-RES-0725-03404
Permit Status: Complete
Permit Description: Interior hot & cold repipe of the domestic water distribution system
Start Date Submittal Complete Date Status  
07/08/2025 RESIDENTIAL SIMPLE REVIEW v.1 07/11/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0725-03404
Permit Status: Complete
Permit Description: Interior hot & cold repipe of the domestic water distribution system
Date Description Comments
07/08/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0725-03404
Permite Description: Interior hot & cold repipe of the domestic water distribution system
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
07/15/2025 RSPL - Plumbing Progress N/A Re-inspection required 7.15.25
Pex support missing throughout. Vertical runs must be supported every 48" and horizontal runs must be supported every 32".
Water line leaking at toilet.
Stud over notched at primary bedroom. Shoe or sister stud required.
Excavated run to meter requires inspection BEFORE backfill. Open trench in 3 areas (2'x2'x depth of pipe) at beginning, middle, and end so inspector and confirm proper depth throughout.
Hammer arrester missing at washer in kitchen.
07/15/2025 COT - RSPL - Plumbing Final N/A Re-inspection required 7.15.25
Pex support missing throughout. Vertical runs must be supported every 48" and horizontal runs must be supported every 32".
Water line leaking at toilet.
Stud over notched at primary bedroom. Shoe or sister stud required.
Excavated run to meter requires inspection BEFORE backfill. Open trench in 3 areas (2'x2'x depth of pipe) at beginning, middle, and end so inspector and confirm proper depth throughout.
Hammer arrester missing at washer in kitchen.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0725-03404
Permit Description: Interior hot & cold repipe of the domestic water distribution system
Total Completed Inspections - 2
Date Description Inspector Results Comments
07/16/2025 RSPL - Plumbing Progress Passed
07/16/2025 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BRNB42200BAB205_007513_V1.PDF DOCUMENTS VIEW