Permit: TC-RES-0725-03404

Parcel: 106043290


Addresses:

3256 N INCAS AV

Inspection Status: Re-inspection required

Inspection History: RSPL - Plumbing Progress

Date Description Inspector Results Comments
07/15/2025 RSPL - Plumbing Progress Re-inspection required 7.15.25
Pex support missing throughout. Vertical runs must be supported every 48" and horizontal runs must be supported every 32".
Water line leaking at toilet.
Stud over notched at primary bedroom. Shoe or sister stud required.
Excavated run to meter requires inspection BEFORE backfill. Open trench in 3 areas (2'x2'x depth of pipe) at beginning, middle, and end so inspector and confirm proper depth throughout.
Hammer arrester missing at washer in kitchen.
07/16/2025 RSPL - Plumbing Progress Passed