Permit: TC-RES-0724-04183
Permit Details
Apply Date:
07/17/2024
Applicant:
Bobby Poplin
Description:
Fire Damage Repair CE-VIOO0524-01882
Permit Reviews
Permit Number - TC-RES-0724-04183
Permit Status: Inspections
Permit Description: Fire Damage Repair CE-VIOO0524-01882
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/17/2024 | RESIDENTIAL NEW DWELLING v.1 | 07/17/2024 | REQUIRES RESUBMIT |
07/18/2024 | RESIDENTIAL NEW DWELLING v.2 | 08/21/2024 | APPROVED |
Conditions
Permit Number - TC-RES-0724-04183
Permit Status: Inspections
Permit Description: Fire Damage Repair CE-VIOO0524-01882
Date | Description | Comments |
---|---|---|
08/21/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0724-04183
Permite Description: Fire Damage Repair CE-VIOO0524-01882
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2025 | COT - BULD - SWG Clearance | N/A | Re-inspection required | 1-24-25, pex lines were ran directly to the gas water heater-see ch. 28 of the international residential code for additional information/code requirements. Missing pressure relieve valve, catch pan, and no condensation line extending to the exterior |
01/24/2025 | COT - RSPL - Gas Pressure Test | N/A | Re-inspection required | 1-24-25, pex lines were ran directly to the gas water heater-see ch. 28 of the international residential code for additional information/code requirements. Missing pressure relieve valve, catch pan, and no condensation line extending to the exterior |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0724-04183
Permit Description: Fire Damage Repair CE-VIOO0524-01882
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/20/2024 | BULD - Electrical Clearance | Passed | Okay to energize panel. RECN CLEARANCE ISSUED. | |
01/08/2025 | COT - RSBU - Roof Nailing | Passed | New rafters and plywood is installed over garage. Sheathing is properly nailed and H2.5 clips are installed. Okay to proceed with roofing material on garage. | |
01/08/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | New electrical sub-panel is installed and properly wired. Okay to proceed with further work. |