Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 133323790


Addresses:

401 N BROWN AV


Inspection Status: Not Ready

Inspection History: COT - RSPL - Gas Pressure Test 

Permit Number - TC-RES-0724-04183

Inspection Description - COT - RSPL - Gas Pressure Test 

Inspection Status - Not Ready

Date Description Inspector Results Comments
01/22/2025 COT - RSPL - Gas Pressure Test  Not Ready 1-25-22, not ready-not under pressure. Must be set at 15psi for a minimum of 10 minutes.
01/24/2025 COT - RSPL - Gas Pressure Test  Re-inspection required 1-24-25, pex lines were ran directly to the gas water heater-see ch. 28 of the international residential code for additional information/code requirements. Missing pressure relieve valve, catch pan, and no condensation line extending to the exterior