Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSPL - Gas Pressure Test
Permit Number - TC-RES-0724-04183
Inspection Description - COT - RSPL - Gas Pressure Test
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/22/2025 | COT - RSPL - Gas Pressure Test | Not Ready | 1-25-22, not ready-not under pressure. Must be set at 15psi for a minimum of 10 minutes. | |
01/24/2025 | COT - RSPL - Gas Pressure Test | Re-inspection required | 1-24-25, pex lines were ran directly to the gas water heater-see ch. 28 of the international residential code for additional information/code requirements. Missing pressure relieve valve, catch pan, and no condensation line extending to the exterior |