Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1221 E SENECA ST
Apply Date:
07/21/2023
Applicant:
Charles AUBENY
Description:
CE-VIO0323-02524 Renovate SFR Enclose Porch

Permit Reviews

Permit Number - TC-RES-0723-06722
Permit Status: Complete
Permit Description: CE-VIO0323-02524 Renovate SFR Enclose Porch
Start Date Submittal Complete Date Status  
10/25/2023 RESIDENTIAL NEW DWELLING v.4 11/13/2023 REQUIRES RESUBMIT Review Details
07/27/2023 RESIDENTIAL NEW DWELLING v.1 08/15/2023 REQUIRES RESUBMIT Review Details
09/19/2023 RESIDENTIAL NEW DWELLING v.3 10/10/2023 REQUIRES RESUBMIT Review Details
03/26/2024 RESIDENTIAL NEW DWELLING v.7 04/26/2024 APPROVED Review Details
02/23/2024 RESIDENTIAL NEW DWELLING v.6 02/23/2024 REQUIRES RESUBMIT Review Details
11/27/2023 RESIDENTIAL NEW DWELLING v.5 11/28/2023 REQUIRES RESUBMIT Review Details
09/15/2023 RESIDENTIAL NEW DWELLING v.2 09/15/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0723-06722
Permit Status: Complete
Permit Description: CE-VIO0323-02524 Renovate SFR Enclose Porch
Date Description Comments
04/26/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0723-06722
Permite Description: CE-VIO0323-02524 Renovate SFR Enclose Porch
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
06/13/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Not Ready
12/24/2024 RSBU - Building Final N/A Re-inspection required 12-24-24, seal water closets, paint/coat condensation line, missing metallic address label on main panel,missing hammer arrestors at laundry room, properly secure mini split condenser to pad, mini split disconnect contains 30 amp fuses and max is 15, water heater located in back bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space and the single wall pipe on water heater requires a 6inch clearance and the b-vent requires 1 inch clearance. Provide a ladder to check the unit on the roof.
12/24/2024 COT - RSEL - Electrical Final N/A Re-inspection required 12-24-24, seal water closets, paint/coat condensation line, missing metallic address label on main panel,missing hammer arrestors at laundry room, properly secure mini split condenser to pad, mini split disconnect contains 30 amp fuses and max is 15, water heater located in back bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space (see ch.20 of the 2018 IRC)and the single wall pipe on water heater requires a 6inch clearance and the b-vent requires 1 inch clearance. Provide a ladder to check the unit on the roof.
12/24/2024 COT - RSME - Mechanical Final N/A Re-inspection required 12-24-24, seal water closets, paint/coat condensation line, missing metallic address label on main panel,missing hammer arrestors at laundry room, properly secure mini split condenser to pad, mini split disconnect contains 30 amp fuses and max is 15, water heater located in back bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space (see ch.20 of the 2018 IRC)and the single wall pipe on water heater requires a 6inch clearance and the b-vent requires 1 inch clearance. Provide a ladder to check the unit on the roof.
12/24/2024 COT - RSPL - Plumbing Final N/A Re-inspection required 12-24-24, seal water closets, paint/coat condensation line, missing metallic address label on main panel,missing hammer arrestors at laundry room, properly secure mini split condenser to pad, mini split disconnect contains 30 amp fuses and max is 15, water heater located in back bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space (see ch.20 of the 2018 IRC)and the single wall pipe on water heater requires a 6inch clearance and the b-vent requires 1 inch clearance. Provide a ladder to check the unit on the roof.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0723-06722
Permit Description: CE-VIO0323-02524 Renovate SFR Enclose Porch
Total Completed Inspections - 8

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1221 E SENECA HOUSE PLANS 5PAGES REV 1 3-7_V1.PDF DOCUMENTS VIEW