Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSME - Mechanical Final
Permit Number - TC-RES-0723-06722
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2025 | COT - RSME - Mechanical Final | Passed | ||
12/24/2024 | COT - RSME - Mechanical Final | Re-inspection required | 12-24-24, seal water closets, paint/coat condensation line, missing metallic address label on main panel,missing hammer arrestors at laundry room, properly secure mini split condenser to pad, mini split disconnect contains 30 amp fuses and max is 15, water heater located in back bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space (see ch.20 of the 2018 IRC)and the single wall pipe on water heater requires a 6inch clearance and the b-vent requires 1 inch clearance. Provide a ladder to check the unit on the roof. |