Permit: TC-RES-0626-03365
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
6442 E CALLE BOOTIS
Address NEW:
6442 E CALLE BOOTIS
Apply Date:
06/22/2026
Applicant:
RUSS MOSER
Description:
8x47 front porch addition
Permit Reviews
Permit Number - TC-RES-0626-03365
Permit Status: Inspections complete
Permit Description: 8x47 front porch addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/25/2026 | RESIDENTIAL ADD/ALT v.1 | 07/10/2026 | REQUIRES RESUBMIT |
| 07/22/2026 | RESIDENTIAL ADD/ALT v.2 | 07/30/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0626-03365
Permit Status: Inspections complete
Permit Description: 8x47 front porch addition
| Date | Description | Comments |
|---|---|---|
| 07/30/2026 | Pre-Issuance - Required Documents - Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0626-03365
Permite Description: 8x47 front porch addition
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/01/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Improper installation of SDWC truss screws, is it designed to be installed to top plate not to the roof sheating. Please follow diagram in plans for proper install. You may use H2.5s or correct screw installation. No ladder provided for roof nail inspection. 9.1.26 - 1/2 shiplap siding was used for roof sheating, contractor submitted 5/8 T1-11 on the approved plans. - over penetrated fasteners on sheating. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0626-03365
Permit Description: 8x47 front porch addition
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Passed | |
| 09/09/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Passed | |
| 09/09/2026 | RSBU - Building Final | Passed | Passed |