Permit: TC-RES-0624-03623
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
1527 W BREAKWELL ST
Address NEW:
1527 W BREAKWELL ST
Apply Date:
06/14/2024
Applicant:
Derek Green
Description:
Fire Damage Repair
Permit Reviews
Permit Number - TC-RES-0624-03623
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/18/2024 | RESIDENTIAL NEW DWELLING v.1 | 07/22/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-0624-03623
Permit Status: Inspections complete
Permit Description: Fire Damage Repair
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/26/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0624-03623
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required (with fee) | 1/24/25 All the notes from previous inspections have not been completed. There are also various termite damage through structure, compromised integrity of framing. Stopped inspection...next inspector may add more items. Re-inspection with fee required. |
| 01/22/2026 | RSBU - Building Final | N/A | Re-inspection required | 1-22-26: no power to receptacle east wall of living room,at east wall & south wall of family room, missing restroom fan cover, missing valve at restroom lavatory, missing anti-tip device at stove, missing hammer arrestors for dishwasher, insulate hot water line of water heater with R3 insulation, missing electrical receptacle behind refrigerator, missing receptacle covers at garage, behind refrigerator, remove cover smoke detector in bedroom, lower hallway thermostat to 48" o.c., missing a/c condensation line to lavatories-see detail M2.0 detail's 5 & 8, arch fault breakers are required for habitable areas-living room, kitchen, family room, hallways and bedrooms, missing 4 breakers at main panel-see schedule. STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED. |
| 01/22/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 1-22-26: no power to receptacle east wall of living room,at east wall & south wall of family room, missing restroom fan cover, missing valve at restroom lavatory, missing anti-tip device at stove, missing hammer arrestors for dishwasher, insulate hot water line of water heater with R3 insulation, missing electrical receptacle behind refrigerator, missing receptacle covers at garage, behind refrigerator, remove cover smoke detector in bedroom, lower hallway thermostat to 48" o.c., missing a/c condensation line to lavatories-see detail M2.0 detail's 5 & 8, arch fault breakers are required for habitable areas-living room, kitchen, family room, hallways and bedrooms, missing 4 breakers at main panel-see schedule. STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED. |
| 01/22/2026 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | 1-22-26: no power to receptacle east wall of living room,at east wall & south wall of family room, missing restroom fan cover, missing valve at restroom lavatory, missing anti-tip device at stove, missing hammer arrestors for dishwasher, insulate hot water line of water heater with R3 insulation, missing electrical receptacle behind refrigerator, missing receptacle covers at garage, behind refrigerator, remove cover smoke detector in bedroom, lower hallway thermostat to 48" o.c., missing a/c condensation line to lavatories-see detail M2.0 detail's 5 & 8, arch fault breakers are required for habitable areas-living room, kitchen, family room, hallways and bedrooms, missing 4 breakers at main panel-see schedule. STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED. |
| 01/22/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 1-22-26: no power to receptacle east wall of living room,at east wall & south wall of family room, missing restroom fan cover, missing valve at restroom lavatory, missing anti-tip device at stove, missing hammer arrestors for dishwasher, insulate hot water line of water heater with R3 insulation, missing electrical receptacle behind refrigerator, missing receptacle covers at garage, behind refrigerator, remove cover smoke detector in bedroom, lower hallway thermostat to 48" o.c., missing a/c condensation line to lavatories-see detail M2.0 detail's 5 & 8, arch fault breakers are required for habitable areas-living room, kitchen, family room, hallways and bedrooms, missing 4 breakers at main panel-see schedule. STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED. |
| 01/22/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 1-22-26: no power to receptacle east wall of living room,at east wall & south wall of family room, missing restroom fan cover, missing valve at restroom lavatory, missing anti-tip device at stove, missing hammer arrestors for dishwasher, insulate hot water line of water heater with R3 insulation, missing electrical receptacle behind refrigerator, missing receptacle covers at garage, behind refrigerator, remove cover smoke detector in bedroom, lower hallway thermostat to 48" o.c., missing a/c condensation line to lavatories-see detail M2.0 detail's 5 & 8, arch fault breakers are required for habitable areas-living room, kitchen, family room, hallways and bedrooms, missing 4 breakers at main panel-see schedule. STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0624-03623
Permit Description: Fire Damage Repair
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2025 | BULD - Electrical Clearance | Passed | 2 April 25 TEP ELECTRICAL CLEARANCE: ECO |
|
| 04/24/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 01/22/2026 | COT - BULD - SWG Clearance | Passed | 1-22-26: okay to energize meter. Clearance issued to Southwest Gas. | |
| 01/22/2026 | COT - RSBU - Roof Nailing | Passed | 1-22-26: approved. | |
| 01/22/2026 | COT - RSPL - Gas Pressure Test | Passed | 1-22-26: gas pressure test approved. | |
| 02/09/2026 | RSBU - Building Final | Passed | All corrections are made. 2/9/2026 | |
| 02/09/2026 | COT - RSME - Mechanical Final | Passed | All corrections are made. 2/9/2026 | |
| 02/09/2026 | COT - RSEL - Outdoor Lighting | Passed | All corrections are made. 2/9/2026 | |
| 02/09/2026 | COT - RSPL - Plumbing Final | Passed | All corrections are made. 2/9/2026 | |
| 02/09/2026 | COT - RSEL - Electrical Final | Passed | All corrections are made. 2/9/2026 |